Display panel
The display panel has one type and the appearance of the type is shown in below.

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety
protection features may activate and cause the unit to disable.
Inverter Split Type
COOL mode
16°C - 32°C
Room Temperature
(61°F - 90°F)
Outdoor
-25°C - 50°C
(-13°F - 122°F)
Temperature
NOTICE
NOTICE
Room relative humidity less than 80%. If the air conditioner operates in excess of this gure,
the surface of the air conditioner may attract condensation. Please sets the vertical air ow
louver to its maximum angle (vertically to the oor), and set HIGH fan mode.
"
" when Electric heating feature is activated (Not available for this unit)
"
" when TIMER is set.
"
" when the unit is on.
"
"
Alarm indicator.
"
" when Wireless Control feature is activated(some units)
"
" when
pre-heating/
defrost feature is activated.
"
"
Displays temperature, operation feature and Error codes:
"
" when 8℃ heating feature is turned on
"
" when Active Clean feature is turned on
" when WiFi module enters AP mode (some units)
"
"
" when Forced cooling feature is turned on
HEAT mode
0°C - 30°C
(32°F - 86°F)
-25°C - 24°C
(-13°F - 75°F)
FOR OUTDOOR UNITS
DRY mode
WITH AUXILIARY
10°C - 32°C
ELECTRIC HEATER
(50°F - 90°F)
When outside
temperature is below 0°C
(32°F ), we strongly
0°C - 50°C
recommend keeping the
(32°F - 122°F)
unit plugged in at all
time to ensure smooth
ongoing performance.