INVERTER RUN
- PRODUCTION -
N.C.
Relay State: Switched
N.O.
GRID DISCONNECTION
- NO PRODUCTION -
N.C.
Relay State: Idle
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
DISCONNECTION
Yes
CAUSE IS STILL
PRESENT
INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
ERROR
Yes
STILL
PRESENT
10. Alarm
This section of the menu allows you to set the activation status of a relay
(available either as contact normally open – N.O. – or as contact normally
closed – N.C.).
This contact can be used, for example, to: activate a siren or a visual
alarm, control the disconnect device of an external transformer, or control
an external device.
The relay can be set to switch in 4 different modes:
• Production (display text "PRODUCTION")
The relay is activated (state: switched) whenever the inverter connects
to the grid; as soon as the inverter is disconnected from the network (for
whatever reason that caused disconnection), the relay is in its resting
position
No
• Alarm with reset at the end of the alarm signalling process (display
text "ALARM"):
The relay is activated (state: switched) whenever an error is present
(code Exxx) on the inverter; this does not apply to warnings (Warning
– code Wxxx). The alarm returns to its resting position when the alarm
signal ends, i.e. before the inverter checks the grid parameters after the
alarm state. This is because grid control state is not an alarm state but a
state of normal operation.
Alarms for which the relay is activated
E001
E007
E015
E021
E031
E050
E057
No
E002
E003
E010
E011
E016
E017
E022
E023
E032
E033
E051
E053
E058
W003
7 - Operation
E004
E005
E012
E013
E018
E019
E026
E029
E034
E046
E054
E055
E006
E014
E020
E030
E049
E056
79