Wiring Of The Pu Connector; Pin Layout; Using The Cable To Connect The Parameter Unit; System Configuration Examples For Communication Operations - Mitsubishi Electric MELIPM Series Instruction Manual

Magnetic motor drive unit
Table of Contents

Advertisement

3.4 Wiring of the PU Connector

3.4.1 Pin layout

As seen from the drive unit (receptacle side) front
Pins No. 2 and 8 (P5S) provide power to the operation panel. Do
NOTICE
not use them when making RS-485 communication.

3.4.2 Using the cable to connect the parameter unit

Use the optional "FR-CB2 parameter unit connection cable" or commercially
available connector and cable for wiring.
RJ45 connector
Connector
Example: 5-554720-3, Tyco Electronics Corporation
Cable conforming to EIA568 (such as 10BASE-T cable)
Example: SGLPEV 0.5mm × 4P (Twiced pair cable, 4 pairs), Mitsubishi
Cable
(Do not use the No. 2 and 8 pins (P5S).)
The maximum wiring length is 20m.
NOTICE

3.4.3 System configuration examples for communication operations

1) For RS-485 communication operation
Computer
RS-485
interface
/terminal
Splitter
10BASE-T cable
1) SG
2) P5S
3) RDA
4) SDB
8) to 1)
Cable Industries, Ltd.
Station No. 1
Station No. 2
Drive unit
PU
connector
3-13
Get other manuals https://www.bkmanuals.com
5) SDA
6) RDB
7) SG
8)P5S
Station No. n
Drive unit
Drive unit
PU
connector
connector
3. WIRING
PU
Terminating
resistor
3

Advertisement

Table of Contents
loading