3.4 Wiring of the PU Connector
3.4.1 Pin layout
As seen from the drive unit (receptacle side) front
Pins No. 2 and 8 (P5S) provide power to the operation panel. Do
NOTICE
not use them when making RS-485 communication.
3.4.2 Using the cable to connect the parameter unit
Use the optional "FR-CB2 parameter unit connection cable" or commercially
available connector and cable for wiring.
RJ45 connector
Connector
Example: 5-554720-3, Tyco Electronics Corporation
Cable conforming to EIA568 (such as 10BASE-T cable)
Example: SGLPEV 0.5mm × 4P (Twiced pair cable, 4 pairs), Mitsubishi
Cable
(Do not use the No. 2 and 8 pins (P5S).)
The maximum wiring length is 20m.
NOTICE
3.4.3 System configuration examples for communication operations
1) For RS-485 communication operation
Computer
RS-485
interface
/terminal
Splitter
10BASE-T cable
1) SG
2) P5S
3) RDA
4) SDB
8) to 1)
Cable Industries, Ltd.
Station No. 1
Station No. 2
Drive unit
PU
connector
3-13
Get other manuals https://www.bkmanuals.com
5) SDA
6) RDB
7) SG
8)P5S
Station No. n
Drive unit
Drive unit
PU
connector
connector