Note
Refer to the RT Getting Started Guide available on your host computer for more
information about setting up your RT target.
© National Instruments Corporation
After rebooting the PXI controller it will appear in the Remote Systems
category with the assigned name.
Figure 2-4 shows the RT Series PXI target, PXI-8106, configured to
automatically obtain an IP address from a DHCP server, as indicated in the
IP Settings section of the figure.
Figure 2-4. Configuring RT Target Network Settings
Expand the PXI controller view in the Remote Systems branch and
6.
select Software.
7.
Click the Add/Remove Software button in the toolbar to launch the
LabVIEW Real-Time Software Wizard.
8.
Install the LabVIEW Real-Time software and device drivers that you
require on the RT target. Refer to the NI Web site at
enter the info code
software.
After installation of the software the controller will automatically reboot
and you will now be able to program it using LabVIEW Real-Time.
Chapter 2
for the latest information about supported
etspc
2-19
Installation and Configuration
and
ni.com/info
NI PXIe-8130 User Manual