5. PARAMETERS
5.2 Detailed list of parameters
5.2.1 Basic setting parameters ([Pr. PA_ _ ])
No.
Symbol
PA02
**REG
Regenerative option
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 37 Parameter
error] occurs.
Setting
digit
_ _ x x
_ x _ _
x _ _ _
PA03
*ABS
Absolute position detection system
Set this parameter when using the absolute position detection system.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
POINT
Set a value in each "x" in the "Setting digit" columns.
Name and function
Regenerative option selection
00: No regenerative option is used.
For a servo amplifier of 200 W or less, no regenerative
resistor is used.
For a servo amplifier of 0.4 kW to 3 kW, a built-in
regenerative resistor is used.
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
For manufacturer setting
Absolute position detection system selection
0: Disabled (used in the incremental system)
1: Enabled (used in the absolute position detection system)
For manufacturer setting
Explanation
Explanation
5 - 10
Initial
Setting
value
range
[unit]
Refer to the
"Name and
function" column.
Initial
value
00h
0h
0h
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h