Download Print this page

Mitsubishi Electric Melservo JE Series Instruction Manual page 102

Servo amplifier, sscnet iii/h interface ac servo with functional safety

Advertisement

5. PARAMETERS
No.
Symbol
PA25
OTHOV
One-touch tuning - Overshoot permissible level
Set a permissible value of the overshoot amount for one-touch tuning as a percentage of the
in-position range.
However, setting "0" will be 50%.
PA26
*AOP5
Function selection A-5
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PA28
**AOP6
Function selection A-6
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Name and function
Explanation
Torque limit function selection at instantaneous power failure
(instantaneous power failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during operation, you
can save electric energy charged in the capacitor in the servo
amplifier by limiting torque at acceleration. You can also delay the
time to trigger [AL. 10.2 Voltage drop in the main circuit power] with
the instantaneous power failure tough drive function. Doing this will
enable you to set a longer time in [Pr. PF25 SEMI-F47 function -
Instantaneous power failure detection time].
To enable the torque limit function at instantaneous power failure,
select "Enabled (_ 1 _ _)" of "SEMI-F47 function selection" in [Pr.
PA20].
For manufacturer setting
Explanation
Selection of the HG-KN series servo motor maximum speed
Select the maximum speed of the HG-KN series servo motor.
0: A maximum speed of 5000 r/min
1: A maximum speed of 6000 r/min
This digit is disabled when a servo motor other than HG-KN series
is connected.
For manufacturer setting
5 - 17
Initial
Setting
value
range
[unit]
0
0 to 100
[%]
Refer to the
"Name and
Initial
function" column.
value
0h
0h
0h
0h
Refer to the
"Name and
Initial
function" column.
value
0h
0h
0h
0h

Advertisement