7. SPECIAL ADJUSTMENT FUNCTIONS
(b) Return time constant disabled was selected.
The gain switching time constant is enabled. The time constant is disabled at gain return.
The following example shows for [Pr. PB26 (CDP)] = 0201, [Pr. PB27 (CDL)] = 0, and [Pr. PB28
(CDT)] = 100 [ms].
CDP (Gain switching)
Gain switching
OFF
After-switching gain
63.4%
Before-switching gain
CDT = 100 ms
Switching at [Pr. PB28 (CDT)] = 100 [ms] only when gain switching on (when switching)
7 - 21
OFF
ON
Return time constant disabled
Switching at 0 ms