Download Print this page

Mitsubishi Electric Melservo JE Series Instruction Manual page 218

Servo amplifier, sscnet iii/h interface ac servo with functional safety

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT
11.1.3 SSCNET III cable
(1) Model explanations
The numbers in the cable length field of the table indicate the symbol filling the underline "_" in the cable
model. The cables of the lengths with the numbers are available.
Cable model
0.15 m 0.3 m 0.5 m
MR-J3BUS_M
015
MR-J3BUS_M-A
(Note)
MR-J3BUS_M-B
Note. For cables of 30 m or shorter, contact your local sales office.
(2) Specifications
SSCNET III cable model
SSCNET III cable length
Optical
Minimum
cable
bending radius
(cord)
Tension strength
Temperature
range for
operation (Note)
Ambience
Appearance [mm]
Note. This temperature range for use is the value for optical cable (cord) only. The temperature condition for the connector is the same
as that for the servo amplifier.
POINT
Do not look directly at the light generated from the CN1A connector and CN1B
connector of servo amplifier or the end of SSCNET III cable. The light can be a
discomfort when it enters the eye.
Refer to app. 5 for a long distance cable over 50 m and ultra-long bending life
cable.
Cable length
1 m
3 m
5 m
03
05
1
3
MR-J3BUS_M
0.15 m
25 mm
70 N
2.2 ± 0.07
10 m 20 m 30 m 40 m 50 m
5
10
20
30
Description
MR-J3BUS_M-A
0.3 m to 3 m
5 m to 20 m
Enforced covering cable:
Cord: 25 mm
140 N
(Enforced covering cable)
-40 °C to 85 °C
Indoors (no direct sunlight), no solvent or oil
4.4 ± 0.1
4.4 ± 0.1
6.0 ± 0.2
11 - 5
Bending
Application and remark
life
Using standard cord
Standard
inside cabinet
Using standard cable
Standard
outside cabinet
Long
Using long distance
40
50
bending
cable
life
MR-J3BUS_M-B
30 m to 50 m
Enforced covering cable:
50 mm
Cord: 30 mm
420 N
(Enforced covering cable)
-20 °C to 70 °C
4.4 ± 0.4
7.6 ± 0.5
50 mm
980 N

Advertisement

loading