Maintenance
Replacing or Installing Scrub Brushes
(Disk)
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn OFF machine
and remove key.
1. Turn machine power off.
2. Open access cover on deck shroud.
3. Locate release lever, press release lever towards
front of machine to release brush pad. The pad will
drop down when released. Lift deck shroud up and
slide brush/pad assembly out.
4. Remove brush/pad from holder and replace with
new brush/pad.
5. To reinstall, lift deck shroud upward as shown.
Center the brush/pad driver under the brush drive
hub.
Raise brush/pad until it contacts brush driver
assembly. Turn clockwise until release lever plate
locks into position.
6. Check that release lever/plate is completely closed
and pad/brush is securely attached.
NOTE: Damage to driver or brush could occur if not
securely attached.
46
86398220
Operators Manual - Chariot-2 iScrub 20

Replacing or Installing Scrub Pad (Orbital)

FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn OFF machine
and remove key.
1. Turn machine power off.
2. Slide pad under machine deck. Center pad on pad
driver and press together.
Replacing or Installing Scrub Brushes
(Cylindrical)
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn OFF machine
and remove key.
1. Turn machine power off.
2. From right side of machine, lift squeegee latch and
swing side squeegee outward to access brushes.
Squeegee Latch