CHAPTER 1.
This chapter describes items to check when inspecting the installation site and the
grounding and power conditions before installing the OfficeServ 7200.
This chapter also describes the items included in the OfficeServ 7200 package and the
installation procedure.

1.1 Location Conditions

Select a location that satisfies the following conditions for safety, temperature and humidity:

1.1.1 Safety Conditions

The OfficeServ 7200 should not be installed near materials that can cause a fire, such
as explosive gas and inflammables. The OfficeServ 7200 should not be near
equipments that generate electromagnetic waves, such as monitors or copying
machines.
The installation location should be convenient for distributing trunk lines and
extension lines, for connecting power and grounding wires, and for maintenance and
repair.
The OfficeServ 7200 should not be installed in aisles or passageways that are
populated or used for moving equipment.
Always maintain cleanliness to prevent dust from damaging the board-connecting part
of the cabinet.
Before installing the OfficeServ 7200, check items such as the electrical wiring status,
grounding status, voltage and frequency.

1.1.2 Temperature/Humidity Conditions

The conditions for temperature and humidity are as follows:
Operation temperature: 0~45 °C
Storage temperature: -10~+50 °C
Humidity: 10~90 %
The system should be maintained in a cool area with no direct sunlight, and ventilators
should be installed to remove dust.