Model Number Description - Trane Voyager TS 150G Series Installation, Operation And Maintenance Manual

Packaged rooftop air conditioners
Table of Contents

Advertisement

Model Number Description

Model Number Descriptions
T
S
D
1
2
3
All products are identified by a
multiple character model number that
precisely identifies a particular type of
unit. An explanation of the
alphanumeric identification code is
provided. Its use will enable the
owner/operator, installing
contractors, and service engineers to
define the operation, specific
components, and other options for
any specific unit.
When ordering replacement parts or
requesting service, be sure to refer to
the specific model number and serial
number printed on the unit
nameplate.
Digit 1 — Unit Type
T
=
Packaged Cooling, Electric Heat
Digit 2 — Efficiency
S
=
Standard Efficiency
H
=
High Efficiency
Digit 3 — Airflow Configuration
D
=
Downflow
H
=
Horizontal
Digit 4, 5, 6 — Nominal Gross
Cooling Capacity (MBh)
150 = 12½ Tons, 60Hz
155 =
15 Tons, 50Hz
180 = 15 Tons, 60Hz
175 =
17½ Tons, 50Hz
210 = 17½ Tons, 60Hz DOE 2018
211 =
17½ Tons, 60Hz
200 =
20 Tons, 50Hz
240 = 20 Tons, 60Hz
250 =
25 Tons, 50Hz
300 = 25 Tons, 60Hz DOE 2018
301 = 25 Tons, 60Hz
Digit 7 — Major Design
Sequence
F
=
Microchannel Type Condenser
25
Coils
G
=
ASHRAE 90.1-2013 (Fan/
Compressor Staging)
Microchannel Type Evaporator &
Condenser Coils
Digit 8 — Voltage Selection
3
=
208-230/60/3
4
=
460/60/3
W =
575/60/3
K
=
380/60/3
D
=
380-415/50/3
Digit 9 — Unit Controls
R
=
Reliatel
RT-SVX25M-EN
1
5
0
4
5
6
Digit 10 — Heating Capacity
0
=
No Heat
G
=
18 kW Electric Heat
K
=
27 kW Electric Heat
N
=
36 kW Electric Heat
P
=
54 kW Electric Heat
R
=
72 kW Electric Heat
Digit 11 — Minor Design
Sequence
Digit 12, 13 — Service Sequence
00 =
None
01 =
18mm Microchannel Condenser
Coil
Note: '01' only available on select
models.
Digit 14 — Fresh Air Selection
0
=
No Fresh Air
D
=
Econ Dry Bulb w/ Barometric
Relief
F
=
Econ Reference Enthaply w/
Barometric Relief
H
=
Econ Comparative Enthaply w/
Barometric Relief
K
=
Low Leak Econ w/ Barometric
Relief
M =
Low Leak Econ Reference
Enthalpy w/ Barometric Relief
P
=
Low Leak Econ Comparative
Enthalpy w/ Barometric Relief
Digit 15 — Supply Fan/Drive
Type/Motor
0
=
Standard Motor
1
=
Oversized Motor
3
=
High Efficiency Motor
6
=
Single Zone Variable Air Volume
Standard Motor
7
=
Multi-Speed Standard Motor
8
=
Single Zone Variable Air Volume
Oversized Motor
9
=
Multi-Speed Oversized Motor
A
=
Single Zone Variable Air Volume
Standard Motor w/ Shaft
Grounding Ring
B
=
Multi-Speed Standard Motor w/
Shaft Grounding Ring
C
=
Single Zone Variable Air Volume
13
or
Oversized Motor w/ Shaft
Grounding Ring
D
=
Multi-Speed Oversized Motor w/
Shaft Grounding Ring
E
=
VAV Supply Air Temperature
Control - Standard Motor
F
=
VAV Supply Air Temperature
Control - Oversized Motor
G
=
VAV Supply Air Temperature
Control - Standard Motor w/ Shaft
Grounding Ring
H
=
VAV Supply Air Temperature
Control - Oversized Motor w/
Shaft Grounding Ring
G
3
7
8
1
1
1
1
1
1
6
6
R
0
A
9
10
11
Digit 16 — Hinged Service Access /
Filters
0
=
Standard Panels/Standard
22
Filters
A
=
Hinged Access/Standard Filters
B
=
Standard Panels/MERV 8 Filters
C
=
Hinged Access/MERV 8 Filters
D
=
Standard Panels/MERV 13 Filters
E
=
Hinged Access/MERV 13 Filters
Digit 17 — Condenser Coil
Protection
0
=
Standard Coil
1
=
Standard Coil With Hail Guard
4
=
CompleteCoat™Condenser Coil
5
=
CompleteCoat™Condenser Coil
with Hail Guard
Digit 18 — Through The Base
Provisions
0
=
No Through The Base Provisions
A
=
Through The Base Electric
Digit 19 — Disconnect Switch/
11
Circuit Breaker
0
=
No Disconnect/circuit break
1
=
Unit Mounted Non-Fused
Disconnect Switch
2
=
Unit Mounted Circuit Breaker
Digit 20 — Convenience Outlet
Option
0
=
Without Convenience Outlet
A
=
Unpowered Convenience Outlet
B
=
Powered Convenience Outlet
Digit 21 — Communications
Options
0
=
Without Communications Options
1
=
Trane Communications Interface
2
=
Lontalk Communications
6
Interface
6
=
Building Automation Control
Network Communications
Interface
7
=
Air-Fi™ Wireless Communications
Digit 22 — Refrigeration System
Option
0
=
Standard refrigeration system
B
=
Dehumidification (Hot Gas
4,13
Reheat)
Digit 23 — Refrigeration Controls
0
=
Without Refrigeration Controls
9,
18
1
=
Frostat
Digit 24 — Smoke Detector
0
=
Without Smoke Detector
A
=
Return Air Smoke Detector
B
=
Supply Air Smoke Detector
C
=
Return/Supply Air Smoke
Detector
D
=
Plenum Smoke Detector
A
12
22
6
6
6
6
12
5
5
6,
15
24
2,10
19
5

Hide quick links: