Weld-In Adapter With Leakage Hole; Mounting The Device; Required Tool; Installation - Endress+Hauser Liquiphant FTL63 Density Operating Instructions Manual

Vibronic density measurement for liquids specifically for the food and life sciences industries
Hide thumbs Also See for Liquiphant FTL63 Density:
Table of Contents

Advertisement

Liquiphant FTL63 Density
Endress+Hauser
 10
Examples of support in the event of dynamic load
5.1.7

Weld-in adapter with leakage hole

Weld in the weld-in adapter in such a way that the leakage hole is pointing downwards.
This enables any leaks to be detected quickly.
 11
Weld-in adapter with leakage hole
5.2

Mounting the device

5.2.1

Required tool

• Open-ended wrench for sensor installation
• Allen key for housing locking screw
5.2.2

Installation

Aligning the tuning fork using the marking
The tuning fork can be aligned using the marking in such a way that the medium drains
off easily and buildup is avoided.
Markings are labeled on the process connection by means of:
Material specification, thread designation, circle, line or double line
Mounting
A0039742
A0039230
17

Advertisement