Replace A Pa-7000 Series Network Processing Card (Npc) - PaloAlto Networks TECHDOCS PA-7000 Series Hardware Reference Manual

Firewall
Hide thumbs Also See for TECHDOCS PA-7000 Series:
Table of Contents

Advertisement

Service the PA-7000 Series Firewall Hardware
Figure 17: PA-7080 LFC
STEP 5 |
Remove the new LFC from the antistatic bag. Slide the LFC into the LFC slot, ensuring that
the handles are in the open position. When the card is about 1/4-inch from being fully
inserted, adjust the levers to align with the chassis and then close the levers to seat the card
in place.
The small notches located near the hinge of the card levers are used to fully seat the
card into the back connector of the slot. To prevent damage, ensure that the notches
line up with the chassis so that when you close the levers, the levers fully seat the card
into the backplane connectors.
STEP 6 |
Tighten the thumb screws on each side of the LFC to secure it to the chassis.

Replace a PA-7000 Series Network Processing Card (NPC)

If a Network Processing Card (NPC) fails, the card will reboot and attempt to recover. If the card
does not recover, it will change to a down state. If there is only one functioning NPC in the chassis
PA-7000 Series Firewall Hardware Reference