Danfoss VLT HVAC Drive FC 102 Instruction Manual page 61

Hide thumbs Also See for VLT HVAC Drive FC 102:
Table of Contents

Advertisement

Specifications
Type Designation
High/Normal Load
Typical Shaft Output at 550 V [kW]
Typical Shaft Output at 690 V [kW]
IP20/Chassis
IP21/Type 1
IP55/Type 12/Type 3R
10)
Output current
Continuous (3 x 525–550 V) [A]
Intermittent (60 s overload) (3 x 525–550 V) [A]
Continuous (3 x 551–690 V) [A]
Intermittent (60 s overload) (3 x 551–690 V) [A]
Continuous kVA (550 V AC) [kVA]
Continuous kVA (690 V AC) [kVA]
Max. input current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 690 V) [A]
Intermittent (60 s overload) (at 690 V) [A]
Max. pre-fuses
1)
[A]
Additional specifications
Estimated power loss at rated max. load [W]
Max. cable cross-section (line power and motor) [mm
Max. cable cross-section (load sharing and brake) [mm
Max. cable size with line power disconnect [mm
3)
Efficiency
Table 8.10 Line Power Supply 3 x 525–690 V - Normal overload 110% for 1 minute, P37K-P90K
1) For type of fuse see chapter 8.8 Fuses and Circuit Breakers.
2) American Wire Gauge.
3) Efficiency measured at nominal current. For energy efficiency class see chapter 8.4.1 Ambient Conditions. For part load losses see
www.danfoss.com/vltenergyefficiency.
4) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/
vltenergyefficiency.
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively. Motor and mains
cable: 300 MCM/150 mm
2
.
6) A2+A3 may be converted to IP21 using a conversion kit. See also Mechanical mounting and IP21/Type 1 Enclosure kit in the Design Guide.
7) B3+4 and C3+4 may be converted to IP21 using a conversion kit. See also Mechanical mounting and IP21/Type 1 Enclosure kit in the Design
Guide.
8) 2 wires are required.
9) Variant not available in IP21.
10) Type 3R is not available in the A4 enclosure.
MG11AK22
Instruction Manual
P37K
NO
30
37
B4
C2
C2
43
47.3
41
45.1
41
49
49
53.9
48
52.8
125
740
2
2)
]/(AWG)
2
]/(AWG)
2)
2
2)
]/(AWG)
0.98
Danfoss A/S © 03/2015 All rights reserved.
P45K
P55K
P75K
NO
NO
37
45
45
55
C3
C3
D3h
C2
C2
C2
C2
54
65
59.4
71.5
95.7
52
62
57.2
68.2
91.3
51.4
61.9
82.9
62.1
74.1
99.2
59
71
64.9
78.1
95.7
58
70
63.8
77
94.6
160
160
160
900
1100
1500
150 (300 MCM)
95 (3/0)
95, 70, 70
(3/0, 2/0, 2/0)
(350 MCM, 300 MCM, 4/0)
0.98
0.98
0.98
P90K
NO
NO
55
75
75
90
D3h
C2
C2
C2
C2
87
105
115.5
83
100
110
100
119.5
87
99
108.9
86
94.3
8
112.7
-
1800
185, 150, 120
0.98
57
8