Download Print this page

Technical Data - Jasic 315P AC/DC Digital Operator's Manual

Advertisement

3

Technical data

Parameter
Input voltage Range
Rated input capacity (KVA)
Rated input power (KW)
Recommended fuse capacity (A)
Rated duty cycle @ 40
0
C
No-load voltage (V)
Insulation class
Cooling mode
Protection class
Overall size (mm)
Weight (kg)
Welding current range MMA(A)
Arc ignition current range MMA(A)
Arc force current range MMA(A)
Initial current range (A)
Peak current range (A)
Base current range (A)
Crater current range (A)
DC pulse frequency range (Hz)
DC pulse duration ratio range (%)
AC frequency range (Hz)
Positive and negative half-wave
time ratio (%)
AC pulse frequency range (Hz)
AC pulse duration ratio range (%)
Upslope time (s)
Downslope time (s)
Pre-flow time (s)
Post-flow time (s)
Spot welding time (s)
Arc ignition mode
Product design may vary due to continual improvements or customer requirements.
JT-200D AC/DC
Single-phase 190~250V AC, 50/60Hz
4.6
4.2
40
TIG: 200@35%- MMA: 160@40%
60
570×350×420
27
DC: 10~160; AC: 20~160
DC: 10~200; AC: 20~200
0~100
DC: 10~200; AC: 20~200
DC: 10~205; AC: 30~205
DC: 10~205; AC: 30~205
DC: 10~200; AC: 20~200
Contact arc ignition, HF arc ignition
Contact arc ignition, HF arc ignition
JT-315D AC/DC
3-phase 280~420V AC, 50/60Hz
TIG: 315@20% - MMA: 250@40%
B B
Forced air cooling
Forced air cooling
IP21S
IP21S
590×375×380
DC: 10~250; AC: 20~250
DC: 10~300; AC: 20~300
DC: 10~320; AC: 20~250
DC: 10~320; AC: 30~320
DC: 10~320; AC: 30~320
DC: 10~320; AC: 20~250
0.5~200
0.5~200
10~90
10~90
20~70
20~70
10~60
10~60
0.5~5.0
0.5~5.0
10~90
10~90
0~60
0~60
0~60
0~60
0~15.0
0~15.0
0~20.0
0~20.0
0.0~8.9
0.0~8.9
9
8.4
40
50
33
0~100
7