Jasic Power Arc 160 PFC Operator's Manual

Jasic Power Arc 160 PFC Operator's Manual

Power arc series
Hide thumbs Also See for Power Arc 160 PFC:

Advertisement

www.jasic.co.uk
Power Arc Series
|
Power Arc 160 PFC (JPA-160PFC)
|
Power Arc 180 (JPA-180SE)
|

Operator Manual

Advertisement

Table of Contents
loading

Summary of Contents for Jasic Power Arc 160 PFC

  • Page 1: Operator Manual

    Power Arc Series Power Arc 160 PFC (JPA-160PFC) Power Arc 180 (JPA-180SE) Operator Manual...
  • Page 2: Serial Number

    Your new product Thank you for selecting this Jasic Technology, Wilkinson Star product. This product manual has been designed to ensure that you get the most from your new product. Please ensure that you are fully conversant with the information provided paying particular attention to the safety precautions.
  • Page 3 SAFETY These general safety norms cover both arc welding machines and plasma cutting machines unless otherwise noted. The equipment must only be used for the purpose it was designed for. Using it in any other way could result in damage or injury and in breach of the safety rules. Only suitably trained and competent persons should use the equipment.
  • Page 4 If ventilation is poor, wear an approved respirator. Read and understand the Material Safety Data Sheets (MSDS’s) and the manufacturer’s instructions for metals, consumable, coatings, cleaners, and de-greasers. Do not weld in locations near any de-greasing, cleaning, or spraying operations. Be aware that heat and rays of the arc can react with vapours to form highly toxic and irritating gases.
  • Page 5 Always ensure machine covers and protective devices are in operation. Precautions against fire and explosion Avoid causing fires due to sparks and hot waste or molten metal Ensure that appropriate fire safety devices are available near the cutting / welding area. Remove all flammable and combustible materials from the cutting / welding zone and surrounding areas Do not cut/weld fuel and lubricant containers, even if empty.
  • Page 6: Product Overview

    dangerous to the operator. When the equipment is scrapped, it should be dismantled separating components according to the type of materials. Do not dispose of the equipment with normal waste. The European Directive 2002/96/EC on Waste Electrical and Electronic Equipment states the electrical equipment that has reached its end of life must be collected separately and returned to an environmentally compatible recycling facility.
  • Page 7 • Working frequency is beyond the audio range, which almost eliminates noise pollution. • Industry leading control system • Advanced control technology meets the various welding applications and provides excellent welding performance. • It can be used with a wide range of welding electrodes. •...
  • Page 8 Unpacking Check the packaging for any signs of damage. Carefully remove the machine and retain the packaging until the installation is complete. Location The machine should be located in a suitable position and environment. Care should be taken to avoid moisture, dust, steam, oil or corrosive gases Place on a secure level surface and ensure that there is adequate clearance around the machine to ensure natural airflow.
  • Page 9: Operation

    TIG Welding Insert the cable plug with the work clamp into the “+” socket on the front panel of the welding machine, and tighten it clockwise. Insert the cables plug of the TIG torch into the “-” socket on the front panel of the machine and tighten clockwise.
  • Page 10 TIG mode Connect the TIG torch leads as detailed above. Ensure that a suitable inert gas supply is connected. Switch the power switch on the back panel to “ON”. Select the TIG welding mode using the selector switch. There is voltage output at both output terminals. After the parameters are set appropriately, open the gas valve of the cylinder, the gas valve on the torch and adjust the gas regulator to obtain the desired flow rate.
  • Page 11: Maintenance And Troubleshooting

    Machine operated outside duty cycle. Allow the machine to cool and the unit will reset automatically. Fan not working—Contact the Jasic service centre No power Mains LED lit —Contact the Jasic service centre Mains LED not Lit—Check the mains supply A WILKINSON STAR LIMITED PRODUCT 12-16 ISSUE 1...
  • Page 12: Technical Parameters

    TECHNICAL PARAMETERS Model Technical Parameter Unit ARC160-PFC (JPA-160PFC) ARC180SE (JPA-180) Rated input voltage 95-230 +/- 15% 50/60HZ 230 +/- 15% 50/60 Hz AC110V AC2230V AC230V 3.71 5.02 Rated input power 10~125 10~160 10~180 Welding current range Rated duty cycle (40 9/68 9/68 9/68...
  • Page 13: Parts List

    PARTS LIST JPA-160PFC Part no. Part name Part no. Part name 10004949 Power switch 10006284 10042343 Back panel 10006282 10044009 10043392 Switching power transformer 10043476 Handle 10037147 10043689 Louver 10037146 10007251 IGBT 10059223 Control PCB 10059606 Base 10043393 Main transformer 10044032 Thermal switch 10005833...
  • Page 14 PARTS LIST Part no. Part name Part no. Part name Power switch Thermal switch 10047746 10037859 Back panel Drive transformer 10037125 10037135 10044817 10006284 Handle 10043477 10006282 Louver Switching power transformer 10043689 10037134 10059116 Cover 10006650 Bridge rectifier Base 10037113 10037146 Front panel Control PCB...
  • Page 15: Machine Disposal

    MACHINE DISPOSAL Please do not dispose of electrical waste with normal waste products. In accordance with the European directive 2002/96/EC regarding waste electrical and electronic equipment abnd its implementation into national law any electrical or electronic which has reached its end of life must be collected separately and disposed of via a suitable recycling facility.
  • Page 16 JPA Series Arc 160 PFC Order code JPA-160PFC Arc 180 SE Order code JPA-180SE © Wilkinson Star Limited A WILKINSON STAR LIMITED PRODUCT 12-16 ISSUE 1...