Calrec Argo S Startup Manual page 21

Ip audio routing & mixing system for argo s and argo q consoles
Table of Contents

Advertisement

AoIP Device Receivers
The user configures AoIP Receivers in
the device, the page shown above right is
accessed from the Devices menu when
the 'Combo 31' device's 'Receivers' tab
is selected, it is used to add/remove and
configure receivers.
The number of receivers shown here for
a Type-R AoIP device is 8, this is based
on there being 1 AoIP interface Primary/
Secondary set, each of which carries
64 channels with each stream carrying 8
channels, thus providing 64/8=8 available
receivers.
Each row on the receiver sub-page
table represents a receiver.
The columns in the table provide the
following information about:-
- Receiver name e.g. Line Out -C31.
- Receiver interface e.g. AoIP 1:Pri.
- Number of channels in each receiver
e.g. 8.
- Codec used e.g. L24.
- Packet time e.g. 125us.
-Sample Rate e.g. 48000Hz.
-Link Offset e.g. 2000us.
Receiver Settings - Device
When the user selects one of the
available receivers or clicks on 'Add
Receiver' at the bottom of the page, a
dialogue box appears allowing the user to
configure the receiver.
VIEWING ONLY
It shows information for
and also settings that can be ADJUSTED.
Receiver Name:
From the image below right, the user can
edit the receiver name by clicking in the
Name field and saving it.
CONNECT> DEVICES>AOIP I/O DEVICE RECEIVERS
CONNECT>DEVICES >AOIP I/O DEVICE RECEIVERS- ADD/EDIT/DELETE
No of Channels in the Receiver:
The maximum number of channels that
can exist in a stream is 80, however a
channel count of either 8 or 16 channels
is more common for receiving groups of
related channels from a source.
Refer to the Connect Application
Guide (926-292).pdf for further
information beyond this simple setup of a
receiver, including Advanced Settings.
21