Projecta IS2000 Instruction Manual page 10

Intelli-start 12/24v lithium jump starter and portable power bank
Table of Contents

Advertisement

UNDERSTANDING YOUR JUMP STARTER
ERROR AND ALARM MESSAGES
Error type
Error detail
Low battery
The internal battery voltage of the IS2000 is
too low for a jump start. Please charge the
IS2000 immediately.
Reverse
The clamps are reverse connected to the
polarity
vehicle battery. The clamps should be
disconnected and reconnect in the correct
polarity.
Overvoltage
The vehicle battery voltage is too high for a
12V DC or 24V DC vehicle. Please disconnect
the clamp and ask a qualified mechanic to
check the vehicle's alternator.
Jump starter
The IS2000 will display the "CHARGER
timeout
TIMEOUT" screen if the charging cycle cannot
be completed in 24 hours.
Short circuit
The IS2000 detected the clamps are short-
circuited. The IS2000 will not jump start until the
short circuit is resolved. Please disconnect the
clamps and check the vehicle electrical system.
Overload
The IS2000 detected excess current (more than
the contactor and internal battery can handle)
occurred. Jump starting will be disabled.
Please disconnect the clamps and check the
vehicle electrical system.
Failure
The IS2000 detected a malfunction of internal
contactors or abnormal internal battery
voltage.
Low
The operating temperature is too low for the
temperature
IS2000 to perform its required functions.
**NOTE: The jump starter can be warmed
up by turning on the flood light, at the
expense of battery charge.**
High
The operating temperature is too high for the
temperature
IS2000 to perform its required functions.
Surge
The jump starter has detected surge protection
protection
system failed. User is advised to contact
failure
customer service.
10
Error display
CHARGING
CHARGING
NOT POSSIBLE
NOT POSSIBLE
35ºC
65ºC
Wait for jump starter
Wait for jump starter
to warm up
to cool down
CHARGING
CHARGING
NOT POSSIBLE
NOT POSSIBLE
35ºC
65ºC
Wait for jump starter
Wait for jump starter
to warm up
to cool down
LOW BATTERY
Charge jump starter
OVERVOLTAGE
DETECTED
30.1V
Disconnect clamps
CHARGING
CHARGING
NOT POSSIBLE
NOT POSSIBLE
35ºC
Wait for jump starter
Wait for jump starter
to warm up
to cool down
USB DISABLED
65ºC
Wait for jump starter
to cool down
USB DISABLED
65ºC
Wait for jump starter
to cool down
USB DISAB
65ºC
65º
Wait for jump sta
to cool down

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IS2000 and is the answer not in the manual?

Questions and answers

Table of Contents