OWNER'S OPERATING AND MAINTENANCE MANUAL
Document No. OM-TMM-2228-13 Rev W
S
Short Base
F
Folding Footrest
B
Battery
A
AC Power
TMM3 Procedure-Chair
1-800-237-3377
CHAMPIONCHAIR.COM

Advertisement

Table of Contents
loading

Summary of Contents for Champion TMM3

  • Page 1 OWNER'S OPERATING AND MAINTENANCE MANUAL Short Base Folding Footrest Battery AC Power TMM3 Procedure-Chair 1-800-237-3377 CHAMPIONCHAIR.COM Document No. OM-TMM-2228-13 Rev W...
  • Page 2: Important Notes About This Manual

    Champion Manufacturing, Inc. assumes no responsibility for damage or injury caused by improper assembly, installation, use, or maintenance of these products. No part of this manual may be duplicated in any form without the prior consent of Champion Manufacturing, Inc. Unauthorized duplication/distribution of these materials may result in civil prosecution to the maximum extent allowed by law.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Important Notes about this Manual ...................... 2 Intended Use Statement .......................... 4 Transportation, Storage, Handling & Disposal ..................4 Preparation: Before You Begin ........................ 4 Power/Cable Requirements ........................5 Safety Precautions ............................ 5 Warnings ............................... 5 Accessory Warnings ..........................7 Cautions ..............................
  • Page 4: Intended Use Statement

    INTENDED USE STATEMENT TMM3 Procedure-Chairs are intended for use in patient treatment, transport and/or recovery within a hospital, clinic, same-day/ambulatory surgery center, or similar environment. The pendant control is NOT INTENDED FOR PATIENT USE. A surgeon and/or clinician must always rely on his or her own clinical knowledge when deciding whether to use a TMM3 Procedure-Chair when treating a patient.
  • Page 5: Power/Cable Requirements

    POWER/CABLE REQUIREMENTS For options A, B & E, see the "Options" section of this manual for additional details regarding powering this product. Only use the power/charging cord that came with your TMM3 Video Fluoroscopy Procedure-Chair. SAFETY PRECAUTIONS WARNING IMPORTANT: PLEASE READ...
  • Page 6 SAFETY PRECAUTIONS – CONTINUED WARNING IMPORTANT: PLEASE READ USE FACTORY APPROVED BATTERIES ONLY Use of non-factory approved batteries will void all warranties and could result in unsatisfactory performance and/or damage. USE CAUTION WHEN STORING OXYGEN CYLINDER UNDER CHAIR To prevent severe gas leakage or rupture of compressed gas cylinder, when placing cylinder under chair, ensure adequate clearance between cylinder and its attached gas equipment (i.e.
  • Page 7: Accessory Warnings

    If mounting accessories to back surgical rails, ensure accessory is properly installed and securely engaged prior to transporting patient or chair and prior to use. Only equipment approved by Champion Manufacturing, Inc. is to be mounted on surgical rails. Champion Manufacturing, Inc. is not responsible for damage and assumes no liability caused by the use of unapproved equipment or accessories.
  • Page 8: Cautions

    TMM3 must be at least 20" from nearest wall or obstruction to allow for full range of activation. Leave chair in lowest position whenever possible. This practice will decrease potential injury during an unsupervised patient egress from chair.
  • Page 9: Emi Cautions

    SAFETY PRECAUTIONS – CONTINUED WARNING IMPORTANT: PLEASE READ EMI CAUTIONS EMI MAY AFFECT CHAIR FUNCTIONALITY Chair may be susceptible to EMI (Electromagnetic Interference) caused by electromagnetic energy emitted from various sources, such as, radio and television stations, amateur radio (HAM) transmitters, citizen band (CB) radios, hand-held “walkie-talkies”, security/police/fire transceivers and other communication devices.
  • Page 10: Important

    SAFETY PRECAUTIONS – CONTINUED WARNING IMPORTANT: PLEASE READ IMPORTANT MAXIMUM PATIENT WEIGHT IS 350 POUNDS (158 KG) Maximum patient weight capacity of chair is 350 pounds. If exceeded, damage to chair could occur. CHAIR IS INTENDED FOR INDOOR USE ONLY To ensure proper operation and extend chair life, only use chair in specified environment. ...
  • Page 11: Product Labels/Diagrams

    WARNING Every three (3) months, inspect all labels and ensure they are legible and not tattered, torn or missing. Refer to the label locations in figure below. If labels need replacing, contact Champion Customer Service at 1-800-237-3377. Item No. Part No.
  • Page 12: Options

    OPTIONS "A" A/C POWER OPTION "B" BATTERY POWER OPTION TMM-208-10 Power Light Label TMA57-15 Universal Charger Assembly TMM-222-10 Charge Battery Label TMM-523-10 Battery Removal Label "F" FOLDING FOOTREST OPTION TMM-202-10 Chair End Warning Label Page 12 of 31 manual Document No.: OM-TMM-2228-13 - Revision: W...
  • Page 13: Operating Instructions

    OPERATING INSTRUCTIONS QUICK RELEASE BACK SECTION 1. LOCATE MANUAL QUICK RELEASE LEVER Back section quick release (red) lever is located under seat on patient’s right side. 2. ACTIVATE RELEASE LEVER To activate quick release of back section, pull the red lever out.
  • Page 14: Caster Brake Operation

    CASTER BRAKE OPERATION BRAKE MODE To activate, press down on red end of either brake pedal located at base of chair. (Fig. 1) NOTE: Brake mode prevents all four casters from swiveling and all wheels from spinning. FIG. 1 NEUTRAL MODE To activate, place either brake pedal into a horizontal position (as shown).
  • Page 15: Side Rail Operation

    SIDE RAIL OPERATION LOWERING SIDE RAIL Grasp top of side rail and push inward slightly, while pulling out red rail release tab. Once released, lower rail. Once the side rail latch is deactivated, the rail can be lowered into the "down" position (below the seat). STOWING SIDE RAIL Once the rail is lowered (“down”...
  • Page 16: Adjusting Side Rail Angle

    ADJUSTING SIDE RAIL ANGLE 1. Remove cushion and seat pan by removing four pan head screws. IMPORTANT: Do not discard seat pan head screws, or additional hardware removed during this step. Parts will be reused after adjustment. FIG. 1 2. Loosen top jam nut. 3.
  • Page 17: Pendant (Controller)

    PENDANT (CONTROLLER) PENDANT IS NOT INTENDED FOR PATIENT’S USE WARNING To prevent damage, pendant can be stored at various locations on the chair when not in use. ENSURE AREA IS CLEAR OF OBSTRUCTIONS PRIOR TO PENDANT USE WARNING To prevent property damage or injury to patient, survey area for possible obstructions prior to pendant use.
  • Page 18: Patient Ingress/Egress

    PATIENT INGRESS/EGRESS PATIENT SHOULD NEVER BE PERMITTED TO ENTER OR EXIT FROM ENDS OF PROCEDURE-CHAIR WHEN IN AN UPRIGHT, PARTIALLY, OR TOTALLY RECLINED WARNING POSITION. EXCESSIVE WEIGHT ON ENDS COULD CAUSE CHAIR TO TILT, RESULTING IN POSSIBLE PATIENT INJURY. IMPORTANT: Follow these instructions for safe and proper patient ingress (entry onto chair) and egress (exit from chair).
  • Page 19: Patient Transfer

    WARNING PATIENT INJURY MAY OCCUR. ALL PATIENT TRANSFERS MUST BE MADE TO RIGHT SIDE OF TMM3-SERIES CHAIR, DUE TO SHAPE OF BACK SECTION, AND NOT TO CHAIR ENDS. IMPORTANT: Follow these instructions for safe and proper patient transfer between chair (in procedure orientation) and another horizontal surface.
  • Page 20: Seat Rotation

    Back and leg sections may ONLY be adjusted SLIGHTLY. • Ensure no damage to chair or imaging device while adjusting chair. ROTATING A TMM3 PROCEDURE-CHAIR 1. With patient in chair, depress RED caster brake pedal to lock caster wheels. 2. Place in chair configuration by pressing "Auto Contour"...
  • Page 21: Options

    OPTIONS “S” OPTION: SHORT BASE For “S” option, wheel base length is 26”. Standard wheel base length is 30”. “F” OPTION: MANUAL FOLDING FOOTREST WHEN POSITIONING FOOTREST, BE WARNING Manual Folding AWARE OF PINCH POINTS Footrest: Stowed NOTE: For patient comfort, stow footrest prior to articulating chair into supine (procedure) position.
  • Page 22: B" Option: Battery Pack

    “B” OPTION: BATTERY PACK REMOVING BATTERY PACK FROM CHAIR FIG. 1 Grasp integrated handle on battery pack and pull away from chair until cam locks disengage. Remove battery from mounting bracket. (Fig. 1) INSTALLING BATTERY PACK ONTO CHAIR Place two round, cam locks on back of battery into square openings of mounting bracket.
  • Page 23: A" Option: Ac Power (For On-Board Batteries & Charger)

    “A” OPTION: AC POWER (FOR ON-BOARD FIG. 1 BATTERIES AND CHARGER) The AC power cord for charging on-board batteries is attached to the chair base and may be stowed by wrapping around storage bracket. (Fig. 1) TO CHARGE ON-BOARD BATTERIES •...
  • Page 24: Cleaning Information

    STEAM AND/OR PRESSURE CLEANING CHAIR WILL VOID WARRANTY. TMM3 PROCEDURE-CHAIR Wipe TMM3 Procedure-Chair (rails, base cover, etc.) with a damp cloth and allow to air dry. NOTE: Clean exterior surfaces of electronics (actuators, battery pack, pendants) with minimal water. Complete above steps as required and/or in accordance with facility policies.
  • Page 25: Pad Set Care

    Contact the manufacturer of the fabric or vinyl used on your pads, pad sets and/or pillows for a current list of approved disinfectants. Refer to the Fabric and Finishes Information page on Champion's website for current links to manufacturer materials.
  • Page 26: Preventative Maintenance

    • Inspect for tattered, torn, Every three All Labels Customer Service for months missing, and illegible labels. new labels.      Call Champion • Test function of each button Every three Service if pendant Pendants • Inspect pendant label to ensure...
  • Page 27: Battery Safety Information

    BATTERY SAFETY INFORMATION TO PREVENT PERSONAL INJURY TO PATIENT AND/OR MEDICAL PERSONNEL, WARNING ENSURE BATTERY REPLACEMENT IS PROPERLY INSTALLED AND SECURELY ENGAGED PRIOR TO USE OF ACCESSORY. TO PREVENT PERSONAL INJURY TO PATIENT AND/OR MEDICAL PERSONNEL, WARNING ENSURE BATTERY REPLACEMENT IS INSTALLED BY PERSONNEL WHO HAVE THOROUGHLY READ INSTALLATION INSTRUCTIONS.
  • Page 28: Battery Life

    BATTERY LIFE NOTE: Battery capacity diminishes over time. Charge batteries regularly to maintain healthy battery life. Champion recommends replacing your battery every two (2) years or sooner if required. WARNING Use of batteries that are NOT factory approved will void any and all warranties.
  • Page 29 In all cases the labeling on the chair at the time of delivery indicates the correct rating for your chair – weight rating should not be exceeded! SPECIFICATIONS TMM3 Procedure-Chair Seat Height 25.1" (64 cm) – 33.0" (84 cm) Seat height (to foot plate) 18"...
  • Page 30: Specifications

    We reserve the right to add or delete products at any time and without prior notice. Always provide your product's specific serial number when ordering any replacement parts. When in doubt, contact a Champion representative (352-854-2929 or 1-800-237-3377) for further information.
  • Page 31: Service & Contact Information

    Information contained in this document is based on the latest product data available at the time of printing. Photography, artwork, text and specifications are subject to change. Photographs may show optional items. Champion Manufacturing Inc. reserves the right to make changes to products, materials, options, and/or specification at any time without notice or obligation. Always provide your product's specific serial number when ordering replacement parts.