10. Specification
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Grid frequency range (Hertz)
Max.efficiency
EU efficiency
MPPT efficiency
Dimensions
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Compliance
DC connection
AC connection
Display
Communication
Warranty
.50.
Solis-30K-LV
1100
600
200
200...850
28.5/28.5
44.5/44.5
2/6
30000
30000
30000
3/PE~220
78.8
78.8
0.8leading~0.8lagging
<3%
60
59.5...60.5
97.0%
96.5%
>99.5%
630W*700H*357D (mm)
63kg
Transformerless
<1 W
-25℃...+60℃
0~100%
TYPE4X
<60 dBA
Intelligent redundant fan-cooling
4000m
UL 1741, IEEE 1547, UL 1699B, UL 1998,
FCC, UL 1741SA
MC4 connector
OT terminal
LCD,2×20 Z.
RS485 , Optional: Wi-Fi, GPRS
5 years (Extend to 20 years)
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Grid frequency range (Hertz)
Max.efficiency
EU efficiency
MPPT efficiency
Dimensions
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Compliance
DC connection
AC connection
Display
Communication
Warranty
10. Specification
Solis-50K-HV
1100
720
200
200...850
22/22/22/22
34.3/34.3/34.3/34.3
4/8
50000
50000
50000
3/PE~480
60.2
66.2
0.8leading~0.8lagging
<3%
60
59.5...60.5
99.0%
98.7%
>99.5%
630W*700H*357D (mm)
63kg
Transformerless
<1 W
-25℃...+60℃
0~100%
TYPE4X
<30 dBA
Natural convection
4000m
UL 1741, IEEE 1547, UL 1699B, UL 1998,
FCC, UL 1741SA
MC4 connector
OT terminal
LCD,2×20 Z.
RS485 , Optional: Wi-Fi, GPRS
5 years (Extend to 20 years)
.51.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solis-30k-lvSolis-50k-hvSolis-60k-hv