Display Information

The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The selectable
information is switched as below order: input voltage, input frequency, PV voltage, MPPTcharging current,
MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in
Watt, DC discharging current, main CPU Version and second CPU Version.
Setting Information
Input voltage/ Output voltage
(Default Display Screen)
Input frequency
AC charging current
PV voltage
PV charging current
PV charging power
LCD display
Input Voltage=230V, output voltage=230V
Input frequency=50Hz
AC charging current=30A
PV voltage=103V
PV charging current=50A
MPPT charging power=1.68KW