Safety instructions Dear user Please note! Congratulations on your purchase of a Faber fire! A quality product from which you will experience It is advisable to always install a screen for the warmth and atmosphere for many years. We...
Detach and mount it together with the control box and remote access door in as C31, outlet via roof low as possible position in the false For a (flat) roof, use a Faber roof outlet with a chimney. (See supplied instruction manual diameter of 100/150mm. 40011721).
Smart Home installation defined in chapter 7 “Checking the installation”. The controller can be connected to an external source, such as a Domotica system, by using a Faber False chimney Interface Unit (article number A9323000). ...
Page 12
Take into account a minimum distance of limits the temperature of the convection air. Use 2mm between plateau and glass support the optional Faber ventilation grids (article number “M” due to expansion of the fireplace. A9296400) or a similar alternative with a minimum (fig.
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 Side glass Checking the installation For cleaning only it’s not necessary to remove the side glass. Checking for gas leaks Check with a gas leak finder all connections and MatriX II and III: pipes for gas leakage.
The ratio CO2 and CO must not be greater than Cleaning 1:100. Remove the front glass (see chapter 5). You can clean the glass with Faber glass polish. Example: This is a specially formulated cleaning agent that CO2 is 4% and CO is 400ppm, measured at the can be ordered at authorized Faber dealers.
Page 15
A simple way to calculate whether the exhaust The Horizontal Length consists of the configuration is possible in combination with your elements H, J, L, M, P and R fireplace, use the “Faber Flue App V2”: (fig. 12.1 and 12.2). Elbows 90° in the horizontal plane:...
Page 16
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 11.1 Restrictor table (100/150) NG MatriX 800/500 I,II,III 2 and 800/650 I,II,III 2 Start length (STL) Vertical (TVH) and Horizontal (THL) 16 < < < <...
Page 22
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 13 Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Bend 90°...
Page 23
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 14 Technical data 14.1 MatriX 800/500 I,II,III 2 Technical data Type indication(s) MatriX 1050x500 I, II, III Matrix 800x500 I, II, III Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8"...
Page 25
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 14.2 MatriX 800/650 I,II,III 2 Technical data Type indication(s) MatriX 1050x650 I, II, III Matrix 800x650 I, II, III Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality Category II2H3P Symbol...
Page 26
Installation manual MatriX 800/500 I,II,III 2 and MatriX 800/650 I,II,III 2 15 Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules as defined in the building regulations. Short roof terminal.
Need help?
Do you have a question about the MatriX 800/500 I 2 and is the answer not in the manual?