Safety instructions Dear user Please note! Congratulations on your purchase of a Faber fire! A quality product from which you will experience It is advisable to always install a screen for the fire- warmth and atmosphere for many years. We rec-...
C31, outlet via roof • If desired, a 2 meter pipe set is available For a (flat) roof, use a Faber roof outlet with a di- (article number 20901530). ameter of 100/150mm. False chimney C91, existing chimney •...
Prepare the gas connection on the regula- also limits the temperature of the convection air. tor. Use the supplied Faber ventilation grids or a similar alternative with a minimum free passage of Positioning the fireplace 200cm² per grid, in the space above the fire, when Take into account the installation requirements building the false chimney.
Page 10
Installation manual MatriX 800/500 RD,ST ney, a horizontal screen plate, made of non-com- Removing the glass bustible material, must be installed just above the ventilation openings. (see A in fig. 1.0 and 1,2). MatriX 800/500 RD Installation and finishing Removing the glass from the front •...
Installation manual MatriX 800/500 RD,ST MatriX 800/500 ST is good. Move or remove any chips/glass granules to create a nice glow bed. • Remove cover strips “A” (fig. 4.2a). • Install the front glass and check the fire Rotate clamp “B” clockwise on both sides image.
There are two measuring pipes between the build- Remove the front glass (see chapter 5). in frame and the front glass (fig. 2.1a,b). You can clean the glass with Faber glass polish. This is a specially formulated cleaning agent that X = measuring pipe air supply can be ordered at authorized Faber dealers.
Page 13
The Horizontal Length consists of the ele- configuration is possible in combination with your ments H, J, L, M, P and R fireplace, use the “Faber Flue App V2”: (fig. 12.1 and 12.2). • Elbows 90° in the horizontal plane:...
Page 17
Installation manual MatriX 800/500 RD,ST 13 Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Bend 90°...
Page 18
Installation manual MatriX 800/500 RD,ST found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Installation manual MatriX 800/500 RD,ST 14 Technical data Technical data Type indication(s) MatriX 800/500 RD,ST Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality Category II2H3P Symbol Unit Reference gas/inlet pressure G20-20 G31-37 mbar Emissions in space heating...
Page 20
Installation manual MatriX 800/500 RD,ST 15 Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules as defined in the building regulations.