Safety instructions Dear user Please note! Congratulations on your purchase of a Faber fire! A quality product from which you will experience It is advisable to always install a screen for the fire- warmth and atmosphere for many years. We rec-...
This appliance must be built into an exist- C31, outlet via roof ing or new false chimney. For a (flat) roof, use a Faber roof outlet with a di- For appliances with flexible gas pipes, the ameter of 100/150mm.
Installation manual MatriX 800/500-650 I,II,III H Preparation and installation 4.5 Positioning the fireplace instructions Take into account the installation requirements (see chapter 3). Place the fireplace at the right place and level it. Gas connection Rough height adjustment: The gas connection must comply with the applica- ...
Page 13
For the height of the plateau, observe limits the temperature of the convection air. Use point N (fig. 2.7 and 2.8). the (optional) Faber ventilation grids (article num- Due to the expansion of the fireplace, ber A9296400) or a similar alternative with a mini- there should be at least 2mm clearance mum free passage of 200cm²...
Page 14
Installation manual MatriX 800/500-650 I,II,III H Removing glass Disassemble the glass strip at the top (fig. 3.6 and 3.7). Place a suction cup and disassemble the Front glass side glass (fig. 3.8). MatriX I H: For replacing the glass repeat the steps in reverse ...
Installation manual MatriX 800/500-650 I,II,III H 4. On an even ash bed glow. When the light guide is placed correctly, light will Attention! shine from the top side of the glass. If this is not the case, the light guide must be repositioned. Start the fire for the first time without the glass installed! Creating ash bed...
Remove the front glass (see chapter 5). There are two measuring pipes between the built- You can clean the glass with Faber glass polish. in frame and the front glass (fig. 2.1). This is a specially formulated cleaning agent that can be ordered at authorized Faber dealers.
Page 17
A simple way to calculate whether the exhaust configuration is possible in combination with your Elbows 90° in the horizontal plane: fireplace, use the “Faber Flue App V2”: Horizontal elbows are elbows entirely in the horizontal plane (fig. 12.1, 12.2 and 12.3 I, K and Q).
Page 18
Installation manual MatriX 800/500-650 I,II,III H 11.1 Restrictor table (100/150) MatriX 800/500 I,II,III H and 800/650 I,II,III H Start length (STL) Vertical (TVH) and Horizontal (THL) 30,2 30,2 40,2 40,2 40,2 50,2 50,2 50,2 60,2 60,2 60,2 70,2 70,2 70,2 70,2 70,2 80,2...
Page 19
Installation manual MatriX 800/500-650 I,II,III H 11.2 Restrictor table (130/200) MatriX 800/500 I,II,III H and 800/650 I,II,III H Start length (STL) Vertical (TVH) and Horizontal (THL) 18 < < < <...
Page 20
Installation manual MatriX 800/500-650 I,II,III H 12 Examples flue material 19 < < < <...
Page 21
Installation manual MatriX 800/500-650 I,II,III H 13 Calculation sheet Start length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Bend 90°...
Page 22
Installation manual MatriX 800/500-650 I,II,III H Found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Page 23
Installation manual MatriX 800/500-650 I,II,III H Technical data 14.1 MatriX 800/500 I,II,III H Technical data Type indication(s) MatriX 800/500 I,II,III H Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality Category II2H3P Symbol Unit Reference gas/inlet pressure G20-20 G31-37 mbar...
Page 24
Installation manual MatriX 800/500-650 I,II,III H 14.2 MatriX 800/650 I,II,III H Technical data Type indication(s) MatriX 800/650 I,II,III H Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality Category II2H3P Symbol Unit Reference gas/inlet pressure G20-20 G31-37 mbar Emissions in space heating mg/kWh...
Page 25
Installation manual MatriX 800/500-650 I,II,III H 15 Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protec- tion you need to comply with the applicable rules as defined in the building regulations. Short roof terminal.
Page 26
Installation manual MatriX 800/500-650 I,II,III H 16 Top view sectional burner 800 I,II,III H 16.1 Position led spots and burners 16.2 Position light guides 25 < < < <...
Page 27
Installation manual MatriX 800/500-650 I,II,III H 17 Log set lay out MatriX 800 I,II,III H Use the included decoration instruction card, or for a clear instruction video, scan the QR code 26 < < < <...