Siemens SIMOTICS L-1FN3 Operating Instructions Manual page 84

Naturally ventilated linear motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

Installation
5.3 Procedure when installing the motor
Mounting the segmented cover
1. Mount the secondary sections with the slide plate removed.
2. Mount the first segment of the cover as follows:
Place the end of the first segment starting from the top in a 45° angle, flush to the outer edge
of the last secondary section.
Then lower the segment in alignment with the secondary section track.
When you sense the magnetic attraction, let loose of the segment.
The segment generally assumes the correct position on its own.
Figure 5-19
3. Check the correct position:
If the first segment of the cover extends to the middle of a secondary section, the position is
correct.
4. Mount all other segments the same way as the first segment.
Figure 5-20
82
Mounting the first segment of the segmented cover
Mounting an additional segment of the segmented cover
Naturally-Cooled 1FN3 Linear Motors