Siemens SIMOTICS L-1FN3 Operating Instructions Manual page 109

Naturally ventilated linear motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

No.
Cause of fault
J
Drive controller gain too high
K
Motor components are rubbing
Foreign bodies in the air gap
Guide rail is tight
L
Poor alignment
M
Shocks from coupled machine
If the fault still cannot be resolved after applying the measures specified above, contact
Technical Support or your local sales partner.
Naturally-Cooled 1FN3 Linear Motors
Operating Instructions, 06/2023, A5E52220465B AB
How to remedy the problem
Adjust the controller
Determine cause and adjust components
Consult the manufacturer
Check that the guide rails are not distorted and are parallel
to one another
Align machine guides
Check coupled machine
Operation
8.2 Handling faults
107

Advertisement

Table of Contents
loading

Table of Contents