Nimh/Nicd Battery Program - Skyrc Q200neo Instruction Manual

Ac/dc multi-function smart charger
Table of Contents

Advertisement

SKYRC Q200neo Instruction Manual

NiMH/NiCd Battery Program

Scroll to select the port and short-press to confirm.
CH A
CHARGE SETTING
Battery Type
NiMH
Battery Cell
6S(7.2V)
Charge
Task
Condition
-6 mV
Charge Current
3.0A
Temp Cut-off
50°C
Start
Back
CH A
CHARGE SETTING
Battery Type
NiMH
Lilo
Battery Cell
6S(7.2V)
LiFe
Task
Charge
LiHV
Condition
-6 mV
NiMH
Charge Current
3.0A
NiCd
Temp Cut-off
50°C
PB
Start
Back
CH A
CHARGE SETTING
Battery Type
NiMH
3S(3.6V)
Battery Cell
6S(7.2V)
4S(4.8V)
Charge
Task
5S(6.0V)
Condition
-6 mV
6S(7.2V)
Charge Current
3.0A
7S(8.4V)
Temp Cut-off
50°C
8S(9.6V)
Start
9S(10.8V)
Back
CH A
CHARGE SETTING
Battery Type
NiMH
Battery Cell
6S(7.2V)
Task
Charge
Condition
-6 mV
Charge
Charge Current
3.0A
Re-Peak
Temp Cut-off
50°C
CYCLE_C_D
Start
CYCLE_D_C
Back
SKYRC Q200neo
14.
ENTER CHARGE
SETTING
Short-press the Scroll Wheel to
enter the CHARGE SETTING.
Select Battery Type
Short-press the Scroll Wheel
to call out the Battery Type
menu, and scroll to select
NiMH.
Select Battery Cell
Scroll to Battery Cell, call out
the menu and scroll to select
the correct battery cells.
Select Task
Scroll to Task, call out the
menu and scroll to select the
working mode.
Select Condition
CH A
CHARGE SETTING
Battery Type
NiMH
-3mV
Scroll to Condition, call out
Battery Cell
6S(7.2V)
-4mV
Task
Charge
the menu and set the delta
-5mV
Condition
-6 mV
voltage.
-6mV
Charge Current
3.0A
-7mV
Temp Cut-off
50°C
-8mV
Start
-9mV
Back
Set Charge/Discharge
CH A
CHARGE SETTING
Current
Battery Type
NiMH
2.7A
Battery Cell
6S(7.2V)
2.8A
Task
Charge
Scroll to Charge/Discharge
2.9A
Condition
-6 mV
3.0A
Current, call out the menu and
Charge Current
3.0A
3.1A
scroll to select the current
Temp Cut-off
50°C
3.2A
Start
3.3A
Back
Start
CH A
CHARGE SETTING
Battery Type
NiMH
Short-press the Scroll Wheel
Battery Cell
6S(7.2V)
Charge
Task
to confirm and initiate the
Condition
-6 mV
program.
Charge Current
3.0A
Temp Cut-off
50°C
Start
Back
Stop
A
AL
iPo/6S/Balance CHG
NiMH/6S/Charge
Short-press the Scroll
4.05V
4.05V
1
1
22.42
22.42
Stop Working?
Wheel to stop the program.
V
V
4.05V
4.05V
2
2
OK
4.43
4.43
If prompted to stop, short-
4.05V
4.05V
3
3
A
A
PORT
Press
Back
4.05V
4.05V
4
4
press the Scroll Wheel again
4.05V
4.05V
596mAh
596mAh
5
5
to confirm, or short-press the
4.05V
4.05V
100W 00:30:25
100W 00:30:25
6
6
Port button to return.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sk-100197

Table of Contents