Nr
Error
02102
temperature sensor
reading
02203
heating element
protection
04104
brewer malfunction
10001
I/O-error
10011
heater not
responding
10015
brewer partially
mounted
Description
temperature sensor
reading invalid
heating element is
overheated or defect
CIRCO brewer is blocked
or defect
I/O safety control fails
dosage not within a
reasonable time
the machine cannot
determine the starting
position of the
CIRCO brewer
Reset condition
• press start button, machine
will be restarted
• check the following parts:
» temperature sensor
» I/O board
» all associated wiring
• press start button, machine
will be restarted
• check the following parts:
heating element
» high temperature safety
switches (non-reset-able)
» I/O board
» all associated wiring
• press start button, machine
will be restarted
• follow procedure of section
"CIRCO brewer malfunction
(Error 04104)" in the digital
user manual 700.470.010
• check the following parts:
» CIRCO brewer
» brewer motor
» all associated wiring
• press start button, machine
will be restarted
• check the following parts:
» I/O board
» all associated wiring
• press start button, machine
will be restarted
• check the following parts:
» temperature sensor
» I/O board
» all associated wiring
• press start button, machine
will be restarted
• follow procedure of section
"CIRCO brewer partially
mounted (Error 10015)"
in the digital user manual
700.470.010