Figure 6. Dimensions and Clearances
Flue / Chimney.
The stove is approved for use with 102mm (4 inch) diameter insulated Selkirk insta - lock gas vent.
The spigot is designed to be compatible with a selkirk 4 SIL - DH draft hood connector. The inner sleeve will require
reducing in length so that it prodrudes 25mm below the outer sleeve (See
Figure 7.
Before you install the stove make sure the chimney flue outlet is correctly positioned to align with the flue outlet on the
stove and that the chimney is in good condition. If not, a chimney liner must be installed or a suitable class 2 gas flue
used. A draught is necessary to ensure the products of combustion are fully evacuated. Connect and seal the the stove
flue collar to the chimney using full depth of collar. The flue must have a minimum effective height of 3 metres (10ft),
however to, to ensure optimum performance we recommend 3.66 metres (12ft) or higher. The flue must be free of
obstruction and any dampers must be fixed in a permanently open position. Ensure that the chimney is not closed and
that it has been swept prior to the stove being installed. Make sure that rain, birds or any foreign bodies cannot get into
the chimney and cause blockage or damage. This problem can normally be overcome by fitting an approved Gas Cowl. It
is essential to the effective running of your stove that the chimney draws properly and allows the products of combustion
to escape.