7.1 Checking the aeration setting of the burner.
(For LPG models refer to the conversion guide).
1. The aeration shutter is factory set. It is important to ensure that the aeration setting is correct. Check the aeration shutter
setting (See
figure
10).
Figure 10. Aeration shutter setting
2. To adjust the aeration setting, loosen the two aeration shutter screws, slide the aeration shutter to the position shown in
9
and tighten the fixing screws.
Page 16