Functional Description
4.13.1
System Clock
The system clock is driven by an oscillator. The following table defines the clock frequencies for
various configurations.
Table 4-1 Clock Frequencies
SYSCLK
66.67 MHz
66.67 MHz
4.13.2
Real Time Clock Input
The RTC clock input is driven by a 1 MHz clock generated by the Control and Timers PLD. This
provides a fixed clock reference for the MC864xD PIC timers which software can use as a
known timing reference.
4.13.3
Local Bus Controller Clock Divisor
The Local Bus Controller (LBC) clock output is connected to the PLD but is not used by the
internal logic
4.14
Reset Control Logic
There are multiple sources of reset on the MVME7100. The following sources generate a board
level reset:
Power-up
Reset switch
Watchdog timer
System control register (BRD_RST)
VMEbus reset
A board level hard reset generates a reset for the entire SBC including the processor, local
PCI/PCI-X buses, Ethernet PHYs, serial ports, flash devices, and PLD(s). If the MVME7100 is
configured as the VME system controller, the VMEbus and local Tsi148 reset input are also
reset.
4.15
Real Time Clock Battery
There is an on-board battery holder that provides easy replacement of a +3.0 V button cell
lithium battery (BR2325) which provides back-up power to the on-board Real Time Clock. A
battery switching circuit provides automatic switching between the +3.3 V and battery voltages.
74
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Core
1.3 GHz
1.067 GHz
MVME7100 Single Board Computer Installation and Use (6806800E08A)
MPX (Platform)
533 MHz
533 MHz
System Clock
DDR2
266 MHz
266 MHz