GENERAL ARRANGEMENT
(EXPOSED MOTOR, BUILT-IN APPLIANCE)
ARRANGEMENT GENERAL
(MOTEUR EXPOSÉ, APPAREIL INTÉGRÉ)
ALLGEMEINE VERORDNUNG
(FREILIEGENDER MOTOR, EINGEBAUTES GERÄT)
DISPOSIZIONE GENERALE
(MOTORE A VISTA, APPARECCHIO AD INCASSO)
ALGEMENE REGELING
(BLOOTGESTELDE MOTOR, INGEBOUWD APPARAAT)
MOUNTING
• Equipment may be supplied with a pre-fitted bespoke mounting plate, as depicted in the above drawings.
• Refer to drawings for dimensions and mounting detail or alternatively, use the plate as a template.
• Ensure the equipment is securely fixed using all available mounting screws/slots/tabs prior to operation. Screws shall be tightened to 3
Nm (+/– 0.2 Nm).

PRE-INSTALLATION

1. Check the equipment for any signs of damage.
Cables should be free of wear/deformation.
2. Check inlet and outlet ports are free from dirt, dust or
packaging material.
3. Ensure the intended mounting point is suitable to support the
equipment mass.
4. Check the mounting site has sufficient clearance to allow
a minimum 10 mm air gap around the equipment for
ventilation. Inadequate ventilation may cause the equipment
to overheat.
If any of the above points are not deemed a "pass", do not proceed
with installation and rectify as required.
INSTALLATION
1. Secure the equipment to the mount-
ing location.
2. Connect the outlet pipework to the outlet port and return
lines to the tank. Hose clips should be used to ensure a secure
connection.
3. The mains supply cord must be routed and supported in such
a way that it doesn't come into contact with any parts of the
equipment or interconnecting pipework.
4. It is recommended to install a suitably rated protective device,
such as a residual current device (RCD), ground-fault circuit
interrupter (GFCI), or earth-leakage circuit breaker (ELCB).
5. Ensure the mains supply is isolated; connect the equipment
to a suitably rated supply point. Refer to the Technical Data
section for fuse sizing.
ALLMÄNT ORDNING
(EXPONERAD MOTOR, INBYGGD APPARAT)
ACUERDO GENERAL
(MOTOR EXPUESTO, APARATO EMPOTRADO)
a. Equipment fitted with a UK plug has a pre-installed fuse
that is suitably rated for the equipment requirements.
b. Equipment fitted with an EU/North American plug is not
provided with a fuse. Suitable protection must be in place
upstream of the equipment prior to mains connection.
c. Equipment without a plug must have a suitable fuse and
disconnect device installed upstream of the equipment
prior to mains connection.
COMMISSIONING
1. Confirm the equipment has
sufficient ventilation space.
2. Ensure the fluid is clean and the equipment is not obstructed
by ice. Solids can cause jamming, and abrasives can reduce
equipment lifespan.
3. Check the fluid level is sufficient to cover the inlet, but not
exceeding the maximum fluid height.
4. Check the outlet and return pipework is connected securely,
and any valves are open.
5. Power up the equipment and check for correct operation.
a. The equipment should stabilise within 10 seconds of initial
operation.
b. If the equipment does not function as expected, discontin-
ue use and refer to the Troubleshooting section.