Xylem WEDECO EFFIZON SMOevo Series Manual
Xylem WEDECO EFFIZON SMOevo Series Manual

Xylem WEDECO EFFIZON SMOevo Series Manual

Ozone generating system
Table of Contents

Advertisement

Quick Links

English translation of the original German manual
Manual
WEDECO EFFIZON®
Ozone Generating System
SMOevo Series
Atchison_P-1138
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Xylem WEDECO EFFIZON SMOevo Series

  • Page 1 English translation of the original German manual Manual WEDECO EFFIZON® Ozone Generating System SMOevo Series Atchison_P-1138 Rev. 1.0...
  • Page 2 26.01.2015 File: Manual_SMOevo610_Atchison_P-1138.doc © Xylem Water Solutions Herford GmbH 2013 The reproduction, distribution and utilization of this document as well as the communication of its contents to others without explicit authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 3: Table Of Contents

    Manual Ozone Generating System SMOevo Table of Contents 1 Table of Contents 1  Table of Contents ......................3  2  About this Manual ......................6  2.1  Contact Addresses ....................6  2.2  Target Group ......................6  2.3  Storage of the Manual .................... 6  2.4 ...
  • Page 4 Manual Ozone Generating System SMOevo Table of Contents 4  Technical Data ......................30  4.1  Type and Identification of the System ..............30  4.2  Operating Data ..................... 31  4.2.1  Dimensions and Weights ................. 31  4.2.2  Cooling Water Requirements and Aeration Requirements ..... 32  4.2.3 ...
  • Page 5 Manual Ozone Generating System SMOevo Table of Contents 7.1.2  Personal Protective Equipment ............... 63  7.1.3  Requirements for the Installation Staff ............ 63  7.1.4  Operating Room ..................63  7.1.5  Installation of the Ozone System ............. 66  7.1.6  Connecting the Ozone System ..............67  7.1.7 ...
  • Page 6: About This Manual

    Xylem Water Solutions Herford GmbH is the full legal name of the manufacturer of WEDECO products. For simplicity's sake, the term WEDECO is used in this manual when referring to Xylem Water Solutions Herford GmbH.
  • Page 7: Liability And Warranty

    Manual Ozone Generating System SMOevo About this Manual 2.4 Liability and Warranty All the data and information concerning operation and maintenance of the system are to the best of our knowledge, based on our previous experience and know-how. We are only liable within the framework of the warranty obligation agreed upon in the main contract for any legal entitlements resulting from this contractual agreement.
  • Page 8: For Your Orientation

    Manual Ozone Generating System SMOevo About this Manual 2.5 For Your Orientation 2.5.1 Pictographs This section gives an outline of the kind of pictographs used in this manual. Pictograph Description Warning signs are triangular with a black pictograph on a yellow background. Prohibition signs are round with the safety color red around the edge and a red transverse bar.
  • Page 9: Abbreviations

    Manual Ozone Generating System SMOevo About this Manual Name of the section Contents of the section Installation and Initial How is the ozone system installed? What do I have to observe Start-Up, prior to commissioning? section 7 Cleaning , How do I clean the ozone system? What is to be observed? section 8 Maintenance, How do I keep the ozone system in functional condition? What...
  • Page 10: Safety

    Manual Ozone Generating System SMOevo Safety 3 Safety This section describes the safety equipment and safety measures relating to the use of the ozone generating system. Read this section carefully prior to operating the system. Ensure that the manual for the system is accessible to the user and the maintenance and repair personnel for the duration of the system service life.
  • Page 11: Definition Of Pictographs And Signal Words

    Manual Ozone Generating System SMOevo Safety The personnel assigned to the installation, commissioning, operation and maintenance of the ozone system and its equipment must read and understand this manual including the safety section. Depending on the qualification of the personnel, additional training might be necessary.
  • Page 12: Hazard Signs

    Manual Ozone Generating System SMOevo Safety 3.2.3 Hazard Signs Warning Signs Pictograph Description Danger! Hazardous voltage! Warning of ozone Warning of suspended loads when loading and unloading Warning of poisonous / toxic substances Warning of explosion hazard Warning of hot surfaces Warning of hazard Warning of electromagnetic field Rev.
  • Page 13 Manual Ozone Generating System SMOevo Safety Prohibiton Signs Pictograph Description Smoking and open flames forbidden Do not spray water Do not touch, live parts Mandatory Signs Pictograph Description Wear ear protection Wear safety gloves Wear safety shoes Wear safety helmet Isolate before working on the system Rev.
  • Page 14 Manual Ozone Generating System SMOevo Safety Safety Signs at the Place of Installation Rooms housing ozone generating systems must be provided with the following warning and prohibition signs: Warning of poisonous substances! Ozone plant! Access for authorized personnel only No persons with pacemaker Smoking and open flames forbidden Safety Signs on the Ozone System Symbol...
  • Page 15: Safety Devices

    Manual Ozone Generating System SMOevo Safety Symbol Description No persons with pacemaker Smoking and open flames forbidden Wear ear protection Ozone labeling on pipework Oxygen labeling on pipework 3.3 Safety Devices This section describes all the available safety equipment and that what is to be provided by the owner / operator.
  • Page 16: Main Switch

    Manual Ozone Generating System SMOevo Safety 3.3.2 Main Switch The main switch of the ozone system is located on the front of the control cabinet. By means of the main switch the complete voltage supply of the ozone generating system is turned on or off.
  • Page 17: Safety And Warning Signs

    Manual Ozone Generating System SMOevo Safety 3.3.7 Safety and Warning Signs All safety and warning signs placed on the ozone system must be clearly legible. Ensure that damaged name plates and warning signs are replaced immediately. 3.4 Responsibilities of the Owner / Operator This section describes the responsibilities of the owner of the ozone generating system and the resulting measures.
  • Page 18: Safety Measures

    Manual Ozone Generating System SMOevo Safety 3.4.2 Safety Measures Personnel The owner / operator of the system is obligated to instruct each person who works with or on this system on the mode of operation, use and the preventive measures which are to be adhered to. The instructed persons have to confirm by signature that they have read and understand all the points in the manual.
  • Page 19 Manual Ozone Generating System SMOevo Safety Detection of The owner / operator must provide appropriate aids and appliances for Ozone measuring the ozone concentration in the ambient air and for detecting leakages. Ozone System The owner / operator is obliged to have the ozone system checked for Check proper condition by a qualified person at least once a year or after modification or repair of the system prior to re-starting.
  • Page 20: Requirements For The Operating Personnel

    Manual Ozone Generating System SMOevo Safety 3.5 Requirements for the Operating Personnel The operating personnel must read and understand this manual and know the applicable regulations regarding operational safety and accident prevention. The operating personnel must accordingly be instructed and trained by the owner / operator of the system.
  • Page 21: Requirements For The Installation Place

    Manual Ozone Generating System SMOevo Safety  The air filter in the breathing mask lasts for approx. 10 minutes  Do not enter the operating room until the ozone concentration has fallen below the alarm limit value.  Preferably use CO fire extinguishers in case of fire.
  • Page 22: Hazardous Substance Ozone

    Manual Ozone Generating System SMOevo Safety Ensure that the monitoring device (measuring sensor) is positioned at a place where the highest ozone concentration is to be expected in the event of a hazardous incident (at ground level). If this concept is taken into account, the alarm value can be set to 1.0 mg/m3 (≈...
  • Page 23: Health Risks

    Manual Ozone Generating System SMOevo Safety 3.7.1 Health Risks Physiologically, ozone acts as an irritant. Particular targets are mucous membranes of the eyes, nose and lungs. Ozone deadens the sense of smell so that the ozone can no longer be perceived in ozone- polluted air even after a short duration of exposure.
  • Page 24: Precautions

    Manual Ozone Generating System SMOevo Safety 3.7.2 Precautions Technical Ensure that rooms housing ozone systems are equipped with a Ventilation technical ventilation system guaranteeing an air exchange of at least three times per hour. An extraction type ventilation system must be available with the intake opening located directly above the floor.
  • Page 25: Hazardous Substance Oxygen

    Manual Ozone Generating System SMOevo Safety 3.8 Hazardous Substance Oxygen The handling of oxygen requires special safety measures which are described in the following section. Oxygen  has a share of ≈ 21 Vol % in the air,  contains two oxygen atoms, ...
  • Page 26: Health Risks

    Manual Ozone Generating System SMOevo Safety 3.8.1 Health Risks A risk to health for humans exists when the oxygen content of respiratory air drops below 17 Vol% or exceeds 21 Vol%. When pure oxygen is inhaled for a prolonged period of time, lung damage and functional disturbances of the autonomic nervous system may occur.
  • Page 27: Residual Risks

    Manual Ozone Generating System SMOevo Safety Operating Rooms Rooms in which oxygen is produced, compressed or in which liquid oxygen is gasified, must be separated gas-tight to adjacent rooms. Adjacent rooms are those which are next to, above and below the rooms in which oxygen is handled.
  • Page 28: Electrical Hazards

    Manual Ozone Generating System SMOevo Safety 3.9.1 Electrical Hazards DANGER! Danger to life due to High Voltage!  Work on live components may be carried out by qualified electricians or electrically instructed personnel under the supervision of a qualified electrician according to the applicable rules of electrical engineering only.
  • Page 29 Manual Ozone Generating System SMOevo Safety CAUTION! Hot System Components! Risk of explosion.  Hot System Components must never get in contact with explosive or highly flammable chemicals. Rev. 1.0 Page 29 of 91...
  • Page 30: Technical Data

    Manual Ozone Generating System SMOevo Technical Data 4 Technical Data The ozone generating systems of the SMOevo series comply with the current state of the art. 4.1 Type and Identification of the System The ozone generators of the SMOevo series are systems for the generation of ozone in the concentration range of up to 15% by weight.
  • Page 31: Operating Data

    Manual Ozone Generating System SMOevo Technical Data 4.2 Operating Data This section gives an overview of important operating data, dimensions and weights of the ozone systems of the SMOevo series. 4.2.1 Dimensions and Weights Type Width Height Depth Operating weight weight 3010mm 2160mm...
  • Page 32: Cooling Water Requirements And Aeration Requirements

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.2.2 Cooling Water Requirements and Aeration Requirements Cooling water Cooling water Aeration requirement requirement requirement Ambient < 25°C 25°C - 35°C Recommended air Heat dissipation to...
  • Page 33: Electrical Connection

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.2.4 Electrical Connection TN-C (L1/L2/L3/PEN) or TN-S (L1/L2/L3/N/PE) network is preferably used for mains connection. Other network configurations (IT of TT) must be agreed with WEDECO prior to placing the order.
  • Page 34: Signal Transfer (Example Of Electrical Wiring Diagram)

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.2.5 Signal Transfer (example of electrical wiring diagram) Rev. 1.0 Page 34 of 91...
  • Page 35 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. The ozone system can be started by an external dry contact (+ 24 V DC) if this operating mode is pre-selected on the touch panel.
  • Page 36 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. If necessary, one more Emergency push button/contact can be included. Rev. 1.0 Page 36 of 91...
  • Page 37: Feed Gas

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.3 Feed Gas Oxygen or air can be used as feed gas. The following table shows the specifications for the feed gases: Oxygen from Oxygen from air liquid tanks...
  • Page 38: Coolant

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.4 Coolant In order to ensure effective ozone production the ozone generator needs to be cooled. The coolant must not contain ...
  • Page 39: Permanent Pressure Level, Sound Pressure, Acoustic Capacity Level

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 4.6 Permanent Pressure Level, Sound Pressure, Acoustic Capacity Level The SMOevo ozone systems were subjected to sound pressure level measurements at a distance of 1m from the frame surface and 1.6m from the floor of the installation place.
  • Page 40: System Description

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5 System Description 5.1 Ozone Generation Principle Besides fluorine, ozone is the strongest oxidizing agent, and if correctly applied, able to contribute enormously to improve the condition of our life and environment.
  • Page 41: Ozone System Design

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.2 Ozone System Design The ozone generating system consists of the ozone generator in which ozone is produced from oxygenic gas, the converter in which the required medium voltage for ozone production is generated, the system control, and the process, measuring and safety controls.
  • Page 42 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Ozone generator The ozone generator is a water-cooled tubular heat exchanger made of stainless steel. The patented WEDECO EFFIZON® HP electrodes made of stainless steel and borosilicate glass form the core of the ozone generating module .
  • Page 43: Process Description Of The System

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3 Process Description of the System 5.3.1 Subassembly 01: Gas Supply BV310-1 Ball valve Gas supply is carried out via a ball valve which must be fully open during normal operation.
  • Page 44 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Do not change the set values at any time! TT310-1 Temperature Measures the feed gas temperature Transmitter 01.0.116 FIT310 Flow meter...
  • Page 45: Subassembly 02: Ozone Generation

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3.2 Subassembly 02: Ozone Generation 02.0.05 Safety valve Opens in case of pressure rise to > 3.5 bar(g) in order to prevent excess pressure in the ozone generator during operation as well as during OFF state .
  • Page 46: Subassembly 03: Process Gas Line

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3.3 Subassembly 03: Process Gas Line BV310-2 Ball valve Isolation valve for PI310-1 03.0.10 PI310-1 Pressure To read the operating pressure of the ozone generator. gauge Refer to the setpoints in section Operating Data.
  • Page 47: Subassembly 07: Cooling System

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3.4 Subassembly 07: Cooling System High temperatures would develop in the ozone generator if ozone was produced without any cooling.
  • Page 48 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. BV310-6 Ball valve Isolation valve for PI310-2 07.0.15 PI310-1 Pressure Displays cooling water inlet pressure indicator 07.0.20 FT/FSL310 Flow meter Indicates cooling water flow rate and transmitts value to PLC.
  • Page 49: Subassembly 23: Converter

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. CV610-2 Actuated ball Is cycled open/shut by the temperature control TC. This valve prevents cold water from flowing through the converter and 07.0.80 possibly forming condensation water when the system is out of operation.
  • Page 50 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. The FU consists of the following main function groups in all its design options:  Power semiconductor kit as a complete assembly with 6-pulse rectifier, designed as a network-driven bridge circuit and IGBT power block.
  • Page 51: Options

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Options 5.3.6 Option CL (Closed Loop) Cooling Water System The Closed Loop cooling water system is designed to separate the cooling water circuit provided by the customer from that of the ozone generator.
  • Page 52 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 07.0.170 PSH330-3 Pressure switch Monitors pressure in closed loop cooling water return line. Set at 45psig. 07.0.175 CKV330-2 Non return valve Prevents cooling water from running in opposite...
  • Page 53 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. DPI330-2 Differential Indicates differential pressure across hot heat pressure indicator exchanger side. 07.0.260 BV330-13 Ball valve Isolation valve for DPI330-2 07.0.265 BV330-14 Ball valve...
  • Page 54: Option Cod (Catalytic Ozone Destructor)

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3.7 Option COD (Catalytic Ozone Destructor) In order to ensure a hazard-free discharge of the off-gas, a residual ozone destructor (COD) must be installed.
  • Page 55: Option M1, M2 And M3 Ozone Monitoring

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.3.8 Option M1, M2 and M3 Ozone Monitoring Measurement, display, and control of ozone concentration by ozone monitor HC-400 plus.
  • Page 56: Process Control

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.4 Process Control 5.4.1 Process Values mO3=cO3 x VG Ozone mass(g/h) The produced ozone mass is the product of the gas volume flow and the ozone concentration: Ozone concentration (g/Nm³...
  • Page 57 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 5.4.2.2 Control of Required Ozone Mass This control option requires ozone concentration measurements (option M2 or M3): In addition to the setpoint Required Ozone Mass another setpoint must be provided: Either the Ozone Concentration or Gas Flow Converter.
  • Page 58 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Based on the Ozone Mass calculated in this way, the Gas Flow or the Ozone Concentration can be defined as setpoint. Refer to section Control of Required Ozone Mass.
  • Page 59: Transport And Storage

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 6 Transport and Storage This section describes the safety measures, the requirements for the personnel and the procedures with regard to transport, packaging and storage of the ozone system.
  • Page 60: Requirements For Transport Staff

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 6.2 Requirements for Transport Staff The ozone system may only be transported by persons who have sufficient experience in the field of transport and fastening of loads.
  • Page 61: Packaging

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 6.4 Packaging 6.4.1 Packaging on Delivery The complete ozone generating system is sealed in foil in order to protect it from soil and rain.
  • Page 62: Installation And Initial Start Up

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 7 Installation and Initial Start Up This section describes the safety measures, the requirements for the personnel, and the procedure with regard to installation and initial start up of the ozone generating system.
  • Page 63: Personal Protective Equipment

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 7.1.2 Personal Protective Equipment To avoid injuries, wear the following protective equipment during installation work: Safety gloves Safety shoes Ear protection 7.1.3 Requirements for the Installation Staff...
  • Page 64 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Space Ensure that the installation area is dimensioned such that requirement operation, maintenance and repair work can be done without hindrances.
  • Page 65 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Ambient Condition Values Ambient temperature for operation 5 °C – 35 °C Ambient humidity for operation < 90 % relative humidity Ambient temperature for transport and storage 0°C to 60°C Ambient humidity for transport and storage...
  • Page 66: Installation Of The Ozone System

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 7.1.5 Installation of the Ozone System  Ensure that no dirt particles get into the system when connecting the system.
  • Page 67: Connecting The Ozone System

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here.  Mark all pipes carrying ozone and oxygen with appropriate labels or coat of paint.  Protect all lines against damage or tearing off. ...
  • Page 68: Purging The System For Drying Out Purposes

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. NOTICE! Hazard due to improper operation! Risk of damage to the system.  It is absolutely necessary to ensure that neither any liquid nor humid gas of downstream reactors or ozone introduction systems is able to flow back into the ozone system.
  • Page 69: Initial Start-Up

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 7.2 Initial Start-Up 7.2.1 Safety Instructions WARNING! Gas containing ozone in system components and pipes! Even during the initial start-up ozone is generated. Hazard of toxic effects and breathing difficulties.
  • Page 70: Setting The Operating Parameters

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here.  The system was tested at the manufacturer’s factory (WEDECO) and can be put into operation once it has been integrated on site.
  • Page 71: Cleaning

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 8 Cleaning This section describes the precautions, the requirements for the personnel and how to proceed with regard to cleaning the ozone system. 8.1 Safety 8.1.1 Safety Instructions DANGER!
  • Page 72: Personal Protective Equipment

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. WARNING! System Components contain ozone! Toxic effects and breathing problems may occur.  Prior to opening ozone-containing System Components, purge the system until no more ozone can be detected, however at least 30 minutes.
  • Page 73: Requirements For The Cleaning Personnel

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 8.2 Requirements for the Cleaning Personnel The ozone system may be cleaned by instructed persons (refer to section Classification of Operating Staff) only.
  • Page 74: Cleaning During Operation

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 8.4.1 Cleaning during Operation Keep the system always clean during operation. Only a clean ozone system guarantees proper operation: ...
  • Page 75: Maintenance

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Maintenance This section describes the precautions, the requirements for the personnel and how to proceed with regard to maintenance work on the ozone system. In order to ensure a long lifetime and low wear of the ozone system, regular maintenance is required.
  • Page 76 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. WARNING! Risk of accident due to not sufficiently qualified personnel! Danger to life or serious injury may result. ...
  • Page 77: Personal Protective Equipment

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 9.2 Personal Protective Equipment In order to avoid injuries, wear the following protective equipment during maintenance and repair work: Ear protection Safety gloves...
  • Page 78 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. During  Use slip-resistant climbing aids or working platforms when maintenance work carrying out work above head-height. ...
  • Page 79: Maintenance Schedule

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 9.5 Maintenance Schedule Some maintenance and inspection work is required to be carried out at certain intervals. The following table gives an overview of the relevant intervals and the work to be done.
  • Page 80 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. P&I No. Component What to do Interval CV310 Check valve Visual inspection every 6 months 03.0.25 SV310-2 Solenoid valve Visual inspection every 6 months...
  • Page 81 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Rev. 1.0 Page 81 of 91...
  • Page 82: Disposing Of Components And Materials

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 9.6 Disposing of Components and Materials Dispose of all the components and materials which have been replaced in a proper and environmentally friendly way.
  • Page 83: Shutdown And Disposal

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 10 Shutdown and Disposal This section describes the precautions, the requirements for the personnel and what to do with regard to final shutdown and disposal of the ozone system.
  • Page 84: Requirements For The Personnel

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. WARNING! Falling load! Danger to life or serious injury may result.  Only use lifting aids and slings permitted to the total weight. ...
  • Page 85: Temporary System Shutdown

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 10.3 Temporary System Shutdown If the ozone system is temporarily to be shut down or if the system is to be employed at another place, proceed as follows: Purge the ozone system with dry oxygen or nitrogen until the lines are free of ozone and an atmospheric dew point of -70°C has been reached.
  • Page 86: Final System Shutdown

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 10.4 Final System Shutdown If the ozone system is finally to be shut down, proceed as follows: Purge the ozone system with dry oxygen or nitrogen until the lines are free of ozone.
  • Page 87: Appendix

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 11 Appendix 11.1 Confirmation of Briefing I hereby confirm that I have completely read and understand the manual related to the ozone generating system SMOevo series.
  • Page 88: Operating Directives

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 11.2 Operating Directives Operating Directives must be issued by the owner / operator of the ozone system. The Directives must be attached well visible for the personnel in the operation room.
  • Page 89 Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Example Directive "Handling of Ozone" Rev. 1.0 Page 89 of 91...
  • Page 90: Swagelok - Installing Instructions For External Connections

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 11.3 Swagelok – Installing Instructions for External Connections Rev. 1.0 Page 90 of 91...
  • Page 91: Spare Parts

    Manual Ozone Generating System SMOevo Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. 11.4 Spare Parts 11.4.1 Disclaimer Only use original WEDECO spare parts and accessories or spare parts and accessories approved by WEDECO.

This manual is also suitable for:

Wedeco effizon smoevo 610