The TDOS5 uses advanced passive infrared sensor to detect heat emitted motion. The sensor switch can turn on a load and keep it on as long as it detects motion. The sensor will automatically shut off the load at the end of the selected time delay. The countdown of the selected time delay starts after the last motion detected. The sensor is customizable with dials that can adjust Time Delay, detection Range, ambient Light Level, and a switch to change between Occupancy/ Vacancy modes.
As illustrated in Figure 1, The TDOS5 has a 180° detection range with a maximum distance of 20' detection in front of the sensor and 10' on the sides. For maximum results, the sensor must be properly installed between the height of 4' to 5' and away from obstructions such as walls, furniture and transparent barriers like Low-E glass.
Turn the POWER OFF at the circuit breaker before installing the sensor
Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the device.
Use copper wires only.
The control panel cover is also the push button on the switch. Remove the push-button cover plate by prying from the bottom of the push-button and pulling outward.
Time dial
This dial adjusts the time delay. Default position: 15 Seconds (Test mode) Adjustable:
from 15 Seconds to 30 Minutes (clockwise)
Range dial
This dial adjusts the detection range. Default position: Center at 65%Adjustable: 30%
(Position 1) to 100% (Position 4).
Note: Use the greater setting for larger coverage area.
Light dial
The sensor may be adjusted to operate at the desired level of ambient light.
Off/ Occupancy/ Vacancy Mode Switch
Mode | Position | Description | Push-button Function |
OFF | Left | Circuit is permanently opened. (switched off) | None |
OCC | Center | Occupancy Mode: Automatic On, Automatic Off after set time delay. | Manually toggles On / Off the load. |
VAC | Right | Vacancy Mode: Manual On only, Automatic Off after set time delay. | Manually toggles On/Off the load. |
Off/ Occupancy/ Vacancy Mode Switch
The OFF position: Switch is turned off and will not detect motion. The push button will not function.
OCCupancy position: The load will automatically turn on when motion is detected and automatically turn off when the selected time delay has expired. The push button may be used to manually turn ON/OFF the load and time delay will also take effect.
VACancy position: The load will turn on ONLY when the push button is used and automatically turn off when the selected time delay has expired. The push button may be used to manually turn ON/OFF the load and time delay will also take effect. If the time delay has expired and the load turns off, the load will turn on again automatically if motion is detected within 30 seconds.
Check the wire connection. Make sure the WHITE wire on the sensor is connected to the NEUTRAL wire in the junction box. DO NOT connect the WHITE wire on the sensor to any other wire besides NEUTRAL. DO NOT connect the WHITE (Neutral) wire and the RED (Load) wire on the sensor together. Otherwise, the load will keep flashing.
The Load does not turn on when motion is detected
Switch Type | Single Pole |
Voltage | 120VAC,60Hz |
Incandescent | 500W |
Fluorescent | 500VA |
Motor | 1/8Hp |
Time Delay | 15Sec to 30Mins |
Light Level | 30 Lux--Daylight |
Operation Temperature | 32ºF--131ºF |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Topgreener TDOS5 - Occupancy/Vacancy 2-In-1 Sensor Switch Installation Manual