Topgreener TDOS5 - Occupancy/Vacancy 2-In-1 Sensor Switch Installation Manual

Topgreener TDOS5 - Occupancy/Vacancy 2-In-1 Sensor Switch Installation Manual

Also See for TDOS5:

Advertisement

Topgreener TDOS5 - Occupancy/Vacancy 2-In-1 Sensor Switch Installation Manual

DESCRIPTION

The TDOS5 uses advanced passive infrared sensor to detect heat emitted motion. The sensor switch can turn on a load and keep it on as long as it detects motion. The sensor will automatically shut off the load at the end of the selected time delay. The countdown of the selected time delay starts after the last motion detected. The sensor is customizable with dials that can adjust Time Delay, detection Range, ambient Light Level, and a switch to change between Occupancy/ Vacancy modes.

COVERAGE

As illustrated in Figure 1, The TDOS5 has a 180° detection range with a maximum distance of 20' detection in front of the sensor and 10' on the sides. For maximum results, the sensor must be properly installed between the height of 4' to 5' and away from obstructions such as walls, furniture and transparent barriers like Low-E glass.
COVERAGE


Turn the POWER OFF at the circuit breaker before installing the sensor
Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the device.
Use copper wires only.

WIRING DIRECTIONS

WIRING DIRECTIONS

  1. Test and Label all wires before installing the sensor. You must have a HOT, NEUTRAL, and LOAD wires in the switch box. DO NOT connect the WHITE (Neutral) wire and the RED (Load) wire on the sensor together. Otherwise, the load will keep flashing.
  2. Connect RED wire from sensor to the LOAD wire.
  3. Connect BLACK wire from sensor to the HOT wire.
  4. Connect WHITE wire from sensor to the NEUTRAL wire. NEUTRAL WIRE IS REQUIRED.
  5. Connect GREEN wire from sensor to the GROUND wire.

ADJUSTMENT

The control panel cover is also the push button on the switch. Remove the push-button cover plate by prying from the bottom of the push-button and pulling outward.
ADJUSTMENT

Time dial
This dial adjusts the time delay. Default position: 15 Seconds (Test mode) Adjustable:
from 15 Seconds to 30 Minutes (clockwise)

Range dial
This dial adjusts the detection range. Default position: Center at 65%Adjustable: 30%
(Position 1) to 100% (Position 4).
Note: Use the greater setting for larger coverage area.

Light dial
The sensor may be adjusted to operate at the desired level of ambient light.

  • To do so, turn the dial counter clockwise for sensor to detect motion and operate during low light or no light. Turn the dial clockwise for sensor to operate when there's more light in the area or even during daylight.

Overview

Off/ Occupancy/ Vacancy Mode Switch

Mode Position Description Push-button Function
OFF Left Circuit is permanently opened. (switched off) None
OCC Center Occupancy Mode: Automatic On, Automatic Off after set time delay. Manually toggles On / Off the load.
VAC Right Vacancy Mode: Manual On only, Automatic Off after set time delay. Manually toggles On/Off the load.

OPERATION

Off/ Occupancy/ Vacancy Mode Switch
The OFF position:
Switch is turned off and will not detect motion. The push button will not function.

OCCupancy position: The load will automatically turn on when motion is detected and automatically turn off when the selected time delay has expired. The push button may be used to manually turn ON/OFF the load and time delay will also take effect.

VACancy position: The load will turn on ONLY when the push button is used and automatically turn off when the selected time delay has expired. The push button may be used to manually turn ON/OFF the load and time delay will also take effect. If the time delay has expired and the load turns off, the load will turn on again automatically if motion is detected within 30 seconds.

TROUBLESHOOTING

The Load Flashes when switch is turned on

Check the wire connection. Make sure the WHITE wire on the sensor is connected to the NEUTRAL wire in the junction box. DO NOT connect the WHITE wire on the sensor to any other wire besides NEUTRAL. DO NOT connect the WHITE (Neutral) wire and the RED (Load) wire on the sensor together. Otherwise, the load will keep flashing.

The Load does not turn on when motion is detected

  1. Keep close to the sensor to make sure you are in the detection range.
  2. Check the LED indicator on the sensor to see whether it flashes when motion is detected. If LED indicator flashes when motion detected, please go to Step 3. If LED indicator stays off when there is motion, please go to Step 4.
  3. Make sure the sensor is in 'OCC' mode.
  4. Check the wiring connection to make sure neutral wire has been connected and make sure Hot and Load wires are not reversely connected.

The Load does not turn off

  1. Manually push the button to turn off the light. If the light keeps on, please go to step 4. If the light is turned off, please go to step 2.
  2. heck the time delay option. The time delay constantly restarts its countdown after the last motion detected. Turn the Time Delay Knob to 15s (Test Mode) and make sure there is no motion (Tape may be used to cover the fresnel lens while testing.)
  3. Check for possible significant heat sources emitting within six feet (two meters) such as high wattage light bulbs, portable heaters or HAVC vents which may be triggering the sensor.
  4. Check the wiring. Make sure no connection between Hot wire and Load.

The Load turns on when not desired

  1. Make sure there is no motion detected by the sensor.
  2. Check for possible significant heat sources emitting within six feet (two meters) such as high wattage light bulbs, portable heaters or HAVC vents which may be triggering the sensor.
  3. If the sensor is installed in a small room, turn the Range dial to a lower setting to avoid false or unwanted detection from a open window or door.
  4. Choose to use VAC mode instead of OCC mode to avoid false triggering.

SPECIFICATIONS

Switch Type Single Pole
Voltage 120VAC,60Hz
Incandescent 500W
Fluorescent 500VA
Motor 1/8Hp
Time Delay 15Sec to 30Mins
Light Level 30 Lux--Daylight
Operation Temperature 32ºF--131ºF

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.