Hikmicro SP60H User Manual
Hikmicro SP60H User Manual

Hikmicro SP60H User Manual

Handheld thermography camera
Hide thumbs Also See for SP60H:
Table of Contents

Advertisement

Quick Links

Handheld Thermography Camera
HIKMICRO SP Series
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hikmicro SP60H

  • Page 1 Handheld Thermography Camera HIKMICRO SP Series User Manual...
  • Page 2 INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
  • Page 3 Handheld Thermography Camera User Manual ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED...
  • Page 4 Handheld Thermography Camera User Manual Regulatory Information These clauses apply only to the products bearing the corresponding mark or information. FCC Information Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 Handheld Thermography Camera User Manual (UK(NI)), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), and Turkey (TR). In accordance with the Radio Equipment Regulations 2017 in the UK, the device working in the 5150 to 5350 MHz frequency range is restricted to indoor use in the United Kingdom.
  • Page 6 Handheld Thermography Camera User Manual cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 7 Handheld Thermography Camera User Manual 取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率、加 大功率或變更原設計之特性及功能。 低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停 用,並改善至無干擾時方得繼續使用。 前述合法通信,指依電信管理法規定作業之無線電通信。 低功率射頻器材須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 應避免影響附近雷達系統之操作。 A 급 기기 : 이 기기는 업무용 (A 급 ) 전자파적합기기로써 판매자 또는 사용자는 이 점을 주의하시기바라며 , 가정 외의 지역에서 사용하는 것을 목적으로 합니다 .
  • Page 8 Handheld Thermography Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, Caution could result in equipment damage, data loss, performance...
  • Page 9 Handheld Thermography Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Please read all the safety information carefully before using. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation ●...
  • Page 10 ● The pollution degree is 2. Technical Support The https://www.hikmicrotech.com/en/contact-us.html portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc. Emergency ●...
  • Page 11 Handheld Thermography Camera User Manual Laser Light Supplement Warning Warning: The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Prevent eyes from direct laser. Before enabling the Light Supplement function, make sure no human or inflammable substances are in front of the laser lens. The wave length is 650 nm, and the power is less than 1 Mw.
  • Page 12: Table Of Contents

    Handheld Thermography Camera User Manual Contents Chapter 1 Overview ........................14 1.1 Device Description ......................14 1.2 Main Function ......................... 14 1.3 Appearance ........................16 Chapter 2 Preparation ........................21 2.1 Cable Connection ......................21 2.2 Charge Battery ........................ 21 2.2.1 Remove Battery ....................
  • Page 13 Handheld Thermography Camera User Manual 3.4 Set Palettes ........................37 3.4.1 Set Alarm Mode Palettes ..................38 3.4.2 Set Focus Mode Palettes ..................38 3.5 Adjust Level & Span ......................39 3.5.1 Color Distribution ....................40 3.6 Adjust Digital Zoom ......................41 3.7 Display OSD Info ......................
  • Page 14 Handheld Thermography Camera User Manual 6.4 Export Files ........................65 Chapter 7 Distance Detection ....................... 66 Chapter 8 Geographic Location Display ..................67 Chapter 9 Direction Display ......................68 9.1 Calibrate Compass ......................68 9.2 Magnetic Declination Correction ..................69 Chapter 10 Device Connections ....................
  • Page 15: Chapter 1 Overview

    Wi-Fi, hotspot and Bluetooth. The built-in high-sensitivity IR detector and high-performance sensor detects the variation of temperature and measure the real-time temperature. Refer to the production specification on HIKMICRO website for detailed information. The built-in laser module detects the target distance.
  • Page 16 For some models that have a micro HDMI output interface, you can connect the device to a display unit to view live image. Client Software Connection ● Mobile Phone: Use HIKMICRO Viewer to see live image, capture, and recording, etc. on your phone. HIKMICRO Viewer Android HIKMICRO Viewer iOS ●...
  • Page 17: Appearance

    Handheld Thermography Camera User Manual 1.3 Appearance...
  • Page 18 Handheld Thermography Camera User Manual...
  • Page 19 Handheld Thermography Camera User Manual Figure 1-1 Buttons and Interfaces Table 1-1 Button and Interface Description Description Function Menu Mode:  Press , and to select parameters.  Press OK to confirm. Navigation Button Non-Menu Mode:  Press to turn on/off the LED light supplement. ...
  • Page 20 Handheld Thermography Camera User Manual Description Function  Press: measure the distance with laser once Laser Button  Hold: measure the distance with laser continuously Hand Strap Attachment Mount the hand strap. Point Neck Strap Attachment 16 & 34 Mount the neck strap. Point Tripod Mount Mount the tripod.
  • Page 21 Handheld Thermography Camera User Manual Caution The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Before enabling the light supplement function, make sure no human or inflammable substances are in front of the laser lens.
  • Page 22: Chapter 2 Preparation

    Handheld Thermography Camera User Manual Chapter 2 Preparation 2.1 Cable Connection Connect the device and power adaptor with a type-C cable to charge the device battery. Alternatively, connect the device and PC to export files. Steps 1. Lift the cable interface cover. 2.
  • Page 23 Handheld Thermography Camera User Manual Figure 2-2 Unlock Battery Compartment 2. Push the inner battery lock (in the black circle) leftwards to release the battery. Figure 2-3 Release Battery 3. Take the battery out of the battery compartment. Figure 2-4 Remove Battery...
  • Page 24: Charge Battery Via Charging Base

    Handheld Thermography Camera User Manual 2.2.2 Charge Battery via Charging Base Note Please charge the battery with the cable and power adapter supplied by the manufacturer (or according to the input voltage from the specifications). Steps 1. Put one or two batteries in the charging base. 2.
  • Page 25 Handheld Thermography Camera User Manual Steps 1. Press the lens release button and turn the interchangeable lens anticlockwise until it stops. Figure 2-6 Release Lens 2. Remove the interchangeable lens carefully. Figure 2-7 Remove Lens 3. Align the two white index marks on the device and the lens. Figure 2-8 Align White Marks 4.
  • Page 26: Mount Hand Strap

    Handheld Thermography Camera User Manual Figure 2-9 Mount Lens 5. Rotate the lens clockwise to fix it. The lens makes a click when it locks in place. Figure 2-10 Fix Lens Note ● Dust on the detector may cause blemishes in the image. If you can find the dust on the detector, use pressurized air from a compressed air canister to blow it off;...
  • Page 27 Handheld Thermography Camera User Manual Figure 2-11 Thread Hand Strap 2. Insert one end of the hand strap through the two hand strap attachment points. Figure 2-12 Thread Hand Strap Through Attachment Points 3. Thread hand strap through the hand strap buckle, and fasten the hand strap. Figure 2-13 Fasten Hand Strap 4.
  • Page 28: Mount Neck Strap

    Handheld Thermography Camera User Manual 2.5 Mount Neck Strap Steps 1. Insert one end of the neck strap through a neck strap attachment point. 2. Thread the neck strap through the buckle, and fasten the neck strap. Figure 2-14 Fasten Hand Strap 3.
  • Page 29: Power On/Off

    Handheld Thermography Camera User Manual Figure 2-16 Tilt Lens and Screen 2.7 Power On/Off Power On Remove the lens cover, and hold for over three seconds to turn on the device. You can observe the target when the interface of the device is stable. Note It may take at least 30 s until the device is ready for using when you power on it.
  • Page 30: Operation Method

    Handheld Thermography Camera User Manual Device Sleep, Scheduled Capture and Video Recording When the device is recording a video clip or on scheduled capturing, auto sleep will not be triggered. However, press will stop the video recording or scheduled capture and force the device into sleep mode.
  • Page 31: Menu Description

    Handheld Thermography Camera User Manual 2.10 Menu Description In the observation interface, tap the screen to show the menu bar, and swipe down to call the swipe-down menu. 2.10.1 Live View Interface Figure 2-19 Live View Table 2-1 Live View Interface Description Descriptions Status bar, where device working status, such as, battery and connections, are displayed.
  • Page 32: Main Menu

    Handheld Thermography Camera User Manual Table 2-2 Description of Status Display Status Display Description Battery Status The device is connected to PC via Type-C cable. Wi-Fi is connected. Memory Card is inserted. Bluetooth is on. Interchangeable Lens is mounted on the device and the interchangeable lens type is on the bottom right of the icon.
  • Page 33: Swipe-Down Menu

    Handheld Thermography Camera User Manual Icon Description Icon Description Level & Span Display Mode Palettes Settings 2.10.3 Swipe-Down Menu In live view interface, swiping on screen from upper to lower to call the swipe-down menu. With this menu, you can turn on/off device function, change display theme, and adjust screen brightness.
  • Page 34: Chapter 3 Display Settings

    Handheld Thermography Camera User Manual Chapter 3 Display Settings Note Your device will periodically perform a self-calibration to optimize image quality and measurement accuracy. In this process the image will pause briefly and you'll hear a "click" as a shutter moves in front of the detector.
  • Page 35: Laser Assisted Focus

    Handheld Thermography Camera User Manual 3.1.2 Laser Assisted Focus Aim the laser to the target and the device focuses automatically. Before You Start ● It is recommended to use this function in a non-glare environment, such as indoor environment. ● The target should have good light reflection, such as white paper and cables. Steps 1.
  • Page 36: Continuous Autofocus

    Handheld Thermography Camera User Manual Figure 3-2 Switch Focus Object 3.1.4 Continuous Autofocus In continuous autofocus mode, the device focuses on the target automatically to make the scene clear. Use this mode when the device is stationary. Caution Disable continuous autofocus mode when the device is moving, or it may affect the device function.
  • Page 37: Set Screen Brightness

    Handheld Thermography Camera User Manual 3.2 Set Screen Brightness The device supports auto or manual screen brightness adjustment. Table 3-1 Screen Brightness Adjustment Method Operation Select , and go to Settings → Device Settings → Screen Manual Brightness to adjust the screen brightness. Or tap , and drag it to adjust the screen brightness.
  • Page 38: Set Palettes

    Handheld Thermography Camera User Manual 2. Press to exit. 3.4 Set Palettes The palettes allow you to select the desired colors. Steps 1. Switch palettes by the following ways: ● Select from the main menu, and tap the icons to select a palette. ●...
  • Page 39: Set Alarm Mode Palettes

    Handheld Thermography Camera User Manual 3.4.1 Set Alarm Mode Palettes Alarm mode palettes allows to mark the targets of certain temperature range with a different color from the rest. Steps 1. Select from the main menu. 2. Tap the icons to select an alarm tool type. Table 3-2 Icon Description Icon Alarm Mode...
  • Page 40: Adjust Level & Span

    Handheld Thermography Camera User Manual Icon Palettes Mode Description Set the temperature threshold, and the targets with Above Focus the temperature higher than the set value are displayed with fusion palettes. Set the temperature threshold, and targets with the Below Focus temperature lower than the set value are displayed with fusion palettes.
  • Page 41: Color Distribution

    Handheld Thermography Camera User Manual details of the area as possible. b. Press , or tap on the value on screen to lock or unlock a value. c. Press , or scroll the adjustment wheel on the screen to fine-tune the max. temperature and the min. temperature respectively.
  • Page 42: Adjust Digital Zoom

    Handheld Thermography Camera User Manual Liner Histogram 3. Press to exit. Note This function is only supported in auto level & span. 3.6 Adjust Digital Zoom In the live view interface, press to zoom in or zoom out by 0.1× continuously. Hold to zoom in or zoom out by 1×, 2×, etc.
  • Page 43: Chapter 4 Temperature Measurement

    Handheld Thermography Camera User Manual Chapter 4 Temperature Measurement The temperature measurement function provides the real-time temperature of the scene and display it on the left of your screen. This function is turned on by default. Note Your device will periodically perform a self-calibration to optimize image quality and measurement accuracy.
  • Page 44: Set Image Measurement

    Handheld Thermography Camera User Manual Set temperature of the external optical material (e.g.: germanium window). Note When you install a macro lens, the device switches to macro mode automatically. In macro mode, settings such as display mode, distance, and optical transmissivity cannot be modified. 3.
  • Page 45: Set Measurement Tool

    Handheld Thermography Camera User Manual 4.3 Set Measurement Tool You can set temperature measurement parameters to improve the accuracy of temperature measurement. Before You Start Set parameters such as Humidity, External Optics Transmittance and Reflection Temperature. For detailed explanations, see Set Measurement Parameters. Steps 1.
  • Page 46: Measure By Line

    Handheld Thermography Camera User Manual Temp. Tap to display or hide the temperature measurement result. 5. Press The temperature of custom spot (e.g. P1) displays P1: XX. Note If the tool-specific emissivity and distance are set, the measurement is conducted based on the parameters.
  • Page 47: Measure By Rectangle

    Handheld Thermography Camera User Manual 4. Tap to modify temperature measurement parameters. Emissivity Refer to Common Material Emissivity Reference to set the emissivity of your target. Distance Set the distance between the target and the device. Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the line can be displayed on the left of the screen.
  • Page 48: Measure By Circle

    Handheld Thermography Camera User Manual Set the distance between the target and the device. Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the rectangle area can be displayed on the left of the screen. 6.
  • Page 49: Measure Δt And Δt Alarm

    Handheld Thermography Camera User Manual Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the circle area can be displayed on the left of the screen. 6. Press to save the settings. Note If the tool-specific emissivity and distance are set, the measurement is conducted based on the parameters.
  • Page 50: Temperature Alarm

    Handheld Thermography Camera User Manual 2) Select Compared Object. Note You can compare the temperature difference between different or the same measurement tools, between a measurement tool and a number, etc. If you select Number as a compared object, input the value manually. 3) Set Alarming ΔT.
  • Page 51: Calculate Area Size

    Handheld Thermography Camera User Manual Alarm Threshold When the tested temperature exceeds the threshold, the device sends alarm notification to the client software. It beeps if the audible warning is enabled. The rectangle flashes red if the rectangle tool is configured. Alarm Linkage ●...
  • Page 52: Chapter 5 Route Inspection

    – Connect your PC to the device hotspot. Turn on and set up device hotspot by Settings → Connections → Hotspot. See Set Device Hotspot for more instructions. 4. Click Device Management to add your device into the client. See the user manual of HIKMICRO Inspector for instructions.
  • Page 53: Perform Route Inspection

    ● Make sure your device has a memory card installed. See Appearance for instructions. ● Connect the device to the PC client, and make sure that your device has received inspection tasks from the PC client. See the user manual of HIKMICRO Inspector for instructions of applying inspection task to the device.
  • Page 54 Handheld Thermography Camera User Manual shows diagnosis options. Figure 5-2 Route Inspection Work Flow Descriptions Inspection task name. Inspect point list. Press to select an inspect point and check the point details. Display inspect point details. Point reference images. They show the parts and angles of targets required for inspection.
  • Page 55: Upload Inspection Result And View Report

    ● You can delete inspection tasks by selecting a task and tapping ● Upload the results to the PC client after finishing the route inspection. See the user manual of HIKMICRO Inspector for instructions. 5.3 Upload Inspection Result and View Report Upload the inspection results to the client software for central management and report generation.
  • Page 56 ● HIKMICRO Analyzer should be installed in your PC. Download the program from https://www.hikmicrotech.com/en/industrial-products/hikmicro-analyzer-software/. ● For the operations instructions in HIKMICRO Analyzer, read the user manual from Help → User Manual. ● Please keep HIKMICRO Analyzer up-to-date for the best compatibility and user experience.
  • Page 57 Handheld Thermography Camera User Manual Figure 5-5 Analysis in HIKMICRO Analyzer...
  • Page 58: Chapter 6 Picture And Video

    Handheld Thermography Camera User Manual Chapter 6 Picture and Video Insert memory card into the device, then you can record videos, capture snapshots, and mark and save important data. Note ● Device does not support capturing or recording when the menu is shown. ●...
  • Page 59 Handheld Thermography Camera User Manual the live image freezes and is saved in the default saving album. If Edit before Saving is enabled, the device enters the image editing interface. Figure 6-1 Edit Image Table 6-1 Editing Options Description Text Note. 1) Tap to enter the editing page.
  • Page 60: Record Video

    Handheld Thermography Camera User Manual ● Continuous Capture/Scheduled Capture: A counter displays in top of the screen showing the completed amount of capturing. 2. Optional: You can set more capture settings as demanded. Table 6-2 More Optional Capture Settings Objective Settings Select , and go to Capture Settings.
  • Page 61 Accidentally stopped recordings are not saved. Recorded videos are saved in .mp4 format. These video clips can be played on local device, and any players that support this format (HIKMICRO Analyzer does not support playing this video format.). 2. Optional: Set frame rate for the selected video type.
  • Page 62: View And Manage Local Files

    File of this format cannot be played on your device. The file extension is determined by the frame rate of a video. Radiometric File Name.rv, or Use HIKMICRO Analyzer to play and analyze the file. Please Videos File Name.hrv upgrade the software to the latest version, otherwise the .hrv file may not be supported.
  • Page 63: Manage Files

    Handheld Thermography Camera User Manual Task Operations Note The newly created album becomes the default saving album and appears at the top of the album list. 1. Press to enter Albums. 2. Select the album to rename. 3. Tap , and select Rename. A soft keyboard is displayed. 4.
  • Page 64 Handheld Thermography Camera User Manual Task Operations 1. Press to enter Albums. 2. Tap to select the album storing the file to be deleted. 3. In the album, tap to select the file to be deleted. 4. Tap , and select Delete. A prompt box appears on the Delete a File interface.
  • Page 65: Edit Images

    Handheld Thermography Camera User Manual 6.3.3 Edit Images Editing the text or voice notes saved with the images, and changing the thermal parameters are allowed on your thermal camera. Note Image editing function varies within the series. See your actual device for available operation options.
  • Page 66: Export Files

    For the first time connection, the driver will be installed automatically. What to do next You can import the captured snapshots to HIKMICRO Analyzer for further data analysis. See the User Manual of HIKMICRO Analyzer (embedded in the client software, Help → User Manual) for...
  • Page 67: Chapter 7 Distance Detection

    Handheld Thermography Camera User Manual Chapter 7 Distance Detection The laser range finder consists of a laser transmitter and a laser receiver. The device detects the distance to a target by measuring the time it takes for a laser pulse to reach the target and return to the laser receiver.
  • Page 68: Chapter 8 Geographic Location Display

    ● In an outdoor space, wait for a moment for the device to display its location. ● The location information is also attached in captured radiometric images. You can read the location by HIKMICRO Analyzer. ● Location display is only supported by models with satellite positioning modules.
  • Page 69: Chapter 9 Direction Display

    Declination Correction for instructions. Note The direction information is also attached in captured radiometric images. You can read the direction by HIKMICRO Analyzer. 9.1 Calibrate Compass Compass calibration is a must for correction direction display. You need to calibrate the compass when you enable the function for the first time.
  • Page 70: Magnetic Declination Correction

    Handheld Thermography Camera User Manual Note ● During calibration, keep moving and rotating the device to make sure that the device faces every possible directions. ● Calibration Level indicates the validity of calibration, higher level means more accurate compass reading. Calibration succeeds when the status bar in the live view interface shows, and Calibrated Level turns to 3.
  • Page 71: Chapter 10 Device Connections

    Handheld Thermography Camera User Manual Chapter 10 Device Connections 10.1 Connect Bluetooth You can record and hear the sound contained in the videos or images via bluetooth headsets after pairing the device with bluetooth headsets successfully. Steps 1. Select , and go to Connections → Bluetooth. 2.
  • Page 72: Set Device Hotspot

    Enable the Wi-Fi function of other equipment and search the password device hotspot to join. a. Tap QR Code. A QR code is displayed. Using hotspot QR code b. Scan the QR code with HIKMICRO Viewer to join the hotspot.
  • Page 73 Handheld Thermography Camera User Manual Note ● When setting the password, do not tap space, or the password may be incorrect. ● The password should be at least 8 digits, consisting of numbers and characters. ● Please tap to enter password into the password field. 4.
  • Page 74: Chapter 11 Thermal View Mobile Client Connection

    Handheld Thermography Camera User Manual Chapter 11 Thermal View Mobile Client Connection The device supports both Wi-Fi connection and hotspot. Connect the device to HIKMICRO Viewer, and you can control the device via mobile client. 11.1 Connect via Wi-Fi Before You Start Download and install HIKMICRO Viewer on your phone.
  • Page 75: Chapter 12 System Settings

    Handheld Thermography Camera User Manual Chapter 12 System Settings 12.1 Set LED Light In live view mode, press to enable/disable the LED light. Or tap on the swipe-down menu. 12.2 Set Unit Select , and go to Device Settings → Unit to set the temperature unit and distance unit. 12.3 HDMI Image Output You can view the image on the display unit for details with this function.
  • Page 76: Chapter 13 Maintenance

    Handheld Thermography Camera User Manual Chapter 13 Maintenance 13.1 View Device Information Select , and go to Local Settings → Device Settings → Device Information to view the device information. 13.2 Upgrade Device Before You Start ● Please download the upgrade file from the official website http://www.hikmicrotech.com or contact the custom service and technical support to get the upgrade file first.
  • Page 77: About Calibration

    Handheld Thermography Camera User Manual memory card. Caution If there are files in the memory card, make sure that the files has been backed up before memory card initialization. Once the card is initialized, data and files cannot be recovered. 13.5 About Calibration We recommend you send the device back for calibration once a year, and please contact the local dealer for the information on maintenance points.
  • Page 78: Chapter 14 Appendix

    Handheld Thermography Camera User Manual Chapter 14 Appendix 14.1 Common Material Emissivity Reference Material Emissivity Human Skin 0.98 Printed Circuit Board 0.91 Concrete 0.95 Ceramic 0.92 Rubber 0.95 Paint 0.93 Wood 0.85 Pitch 0.96 Brick 0.95 Sand 0.90 Soil 0.92 Cloth 0.98 Hard Paperboard...
  • Page 79 Facebook: HIKMICRO Thermography LinkedIn: HIKMICRO Instagram: hikmicro_thermography YouTube: HIKMICRO Thermography E-mail: support@hikmicrotech.com Website: https://www.hikmicrotech.com UD34027B...

This manual is also suitable for:

Sp60Sp series

Table of Contents