Hikmicro SP Series User Manual
Hikmicro SP Series User Manual

Hikmicro SP Series User Manual

Handheld thermography camera
Hide thumbs Also See for SP Series:
Table of Contents

Advertisement

Quick Links

Handheld Thermography Camera
HIKMICRO SP Series
User Manual
Contact Us

Advertisement

Table of Contents
loading

Summary of Contents for Hikmicro SP Series

  • Page 1 Handheld Thermography Camera HIKMICRO SP Series User Manual Contact Us...
  • Page 2 INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
  • Page 3 Handheld Thermography Camera User Manual RISKS, AND HIKMICRO SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKMICRO WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
  • Page 4 Handheld Thermography Camera User Manual Regulatory Information These clauses apply only to the products bearing the corresponding mark or information. FCC Information Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 Handheld Thermography Camera User Manual (UK(NI)), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), and Turkey (TR). In accordance with the Radio Equipment Regulations 2017 in the UK, the device working in the 5150 to 5350 MHz frequency range is restricted to indoor use in the United Kingdom.
  • Page 6 Handheld Thermography Camera User Manual cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 7 Handheld Thermography Camera User Manual A 급 기기 : 이 기기는 업무용 (A 급 ) 전자파적합기기로써 판매자 또는 사용자는 이 점을 주의하시기바라며 , 가정 외의 지역에서 사용하는 것을 목적으로 합니다 .
  • Page 8 Handheld Thermography Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, Caution could result in equipment damage, data loss, performance...
  • Page 9 Handheld Thermography Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Please read all the safety information carefully before using. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation ●...
  • Page 10 ● The pollution degree is 2. Technical Support The https://www.hikmicrotech.com/en/contact-us.html portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc. Emergency ●...
  • Page 11 Handheld Thermography Camera User Manual Laser Light Supplement Warning Warning: The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Prevent eyes from direct laser. Before enabling the Light Supplement function, make sure no human or inflammable substances are in front of the laser lens. The wave length is 650 nm, and the power is less than 1 Mw.
  • Page 12: Table Of Contents

    Handheld Thermography Camera User Manual Contents Chapter 1 Overview ........................1 1.1 Device Description ......................1 1.2 Main Function ........................1 1.3 Appearance ........................3 Chapter 2 Preparation ........................8 2.1 Charge Device ........................8 2.1.1 Charge Device via Cable Interface ................8 2.1.2 Charge Battery via Charging Base................
  • Page 13 Handheld Thermography Camera User Manual 3.6 Adjust Digital Zoom ......................22 3.7 Display OSD Info ......................22 Chapter 4 Temperature Measurement ..................23 4.1 Set Measurement Parameters ..................23 4.1.1 Set Unit ........................ 24 4.2 Set Image Measurement ....................24 4.3 Set Measurement Tool....................
  • Page 14 Handheld Thermography Camera User Manual Chapter 7 Calculate Area Size ....................... 45 Chapter 8 Distance Detection ....................... 46 Chapter 9 Geographic Location Display ..................47 Chapter 10 Direction Display ......................48 10.1 Calibrate Compass ......................48 10.2 Magnetic Declination Correction .................. 49 Chapter 11 Connect Bluetooth .....................
  • Page 15: Chapter 1 Overview

    Wi-Fi, hotspot and Bluetooth. The built-in high-sensitivity IR detector and high-performance sensor detects the variation of temperature and measure the real-time temperature. Refer to the production specification on HIKMICRO website for detailed information. The built-in laser module detects the target distance.
  • Page 16 For some models that have a micro HDMI output interface, you can connect the device to a display unit to view live image. Client Software Connection ● Mobile Phone: Use HIKMICRO Viewer to see live image, capture, and recording, etc. on your phone. HIKMICRO Viewer Android HIKMICRO Viewer iOS ●...
  • Page 17: Appearance

    Handheld Thermography Camera User Manual 1.3 Appearance...
  • Page 18 Handheld Thermography Camera User Manual...
  • Page 19 Handheld Thermography Camera User Manual Figure 1-1 Appearance Table 1-1 Button and Interface Description Description Function Menu Mode:  Press , and to select parameters.  Press OK to confirm. Navigation Button Non-Menu Mode:  Press to turn on/off the LED light supplement. ...
  • Page 20 Handheld Thermography Camera User Manual Description Function Focus Button Press to start focus.  Press: measure the distance with laser once Laser Button  Hold: measure the distance with laser continuously Hand Strap Attachment Mount the hand strap. Point Neck Strap Attachment 16 &...
  • Page 21 Handheld Thermography Camera User Manual Description Function Lens Release Button Unlock the interchangeable lens. Caution The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Before enabling the light supplement function, make sure no human or inflammable substances are in front of the laser lens.
  • Page 22: Chapter 2 Preparation

    Handheld Thermography Camera User Manual Chapter 2 Preparation 2.1 Charge Device 2.1.1 Charge Device via Cable Interface Before You Start Please make sure the battery is installed before charging. Steps 1. Lift the cover of cable interface. 2. Plug in the cable, and connect the power supply to charge the battery. Figure 2-1 Charge Battery via Type-C Cable 2.1.2 Charge Battery via Charging Base Note...
  • Page 23: Mount Hand Strap

    Handheld Thermography Camera User Manual 3. The left and right indicators show the charging status of the batteries. – Solid red: charging normally. – Solid green: fully charged. 4. Draw the battery from the charging base, and disconnect charging base from the power supply. Figure 2-2 Charge Battery via Charging Base 2.2 Mount Hand Strap Steps...
  • Page 24: Change Interchangeable Lens

    Handheld Thermography Camera User Manual Figure 2-4 Thread Hand Strap Through Attachment Points 3. Thread hand strap through the hand strap buckle, and fasten the hand strap. Figure 2-5 Fasten Hand Strap 4. Adjust the tightness of the hand strap as needed. 2.3 Change Interchangeable Lens An interchangeable lens is a thermal lens that can be mounted to the device for obtaining different FOVs, scene scopes, and temperature measurement ranges.
  • Page 25 Handheld Thermography Camera User Manual Figure 2-6 Release Lens 2. Remove the interchangeable lens carefully. Figure 2-7 Remove Lens 3. Align the two white index marks on the device and the lens. Figure 2-8 Align White Marks 4. Push the lens into position.
  • Page 26: Tilt Lens And Screen

    Handheld Thermography Camera User Manual Figure 2-9 Mount Lens 5. Rotate the lens clockwise to fix it. The lens makes a click when it locks in place. Figure 2-10 Fix Lens Note ● Dust on the detector may cause blemishes in the image. If you can find the dust on the detector, use pressurized air from a compressed air canister to blow it off;...
  • Page 27: Power On/Off

    Handheld Thermography Camera User Manual Figure 2-11 Tilt Lens and Screen 2.5 Power On/Off Power On Remove the lens cover, and hold for over three seconds to turn on the device. You can observe the target when the interface of the device is stable. Note It may take at least 30 s until the device is ready for using when you power on it.
  • Page 28: Operation Method

    Handheld Thermography Camera User Manual Press to wake the device up. Device Sleep, Scheduled Capture and Video Recording When the device is recording a video clip or on scheduled capturing, auto sleep will not be triggered. However, press will stop the video recording or scheduled capture and force the device into sleep mode.
  • Page 29: Menu Description

    Handheld Thermography Camera User Manual 2.8 Menu Description In the observation interface, tap the screen to show the menu bar, and swipe down to call the swipe-down menu. ① Shutter ② Level & Span ③ Palettes ④ Temperature Measurement ⑤ Image Mode ⑥...
  • Page 30: Chapter 3 Display Settings

    Handheld Thermography Camera User Manual Chapter 3 Display Settings Note Your device will periodically perform a self-calibration to optimize image quality and measurement accuracy. In this process the image will pause briefly and you'll hear a "click" as a shutter moves in front of the detector.
  • Page 31: Laser Assisted Focus

    Handheld Thermography Camera User Manual 3.1.2 Laser Assisted Focus Point the laser to the target and the device focuses automatically. Danger The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable substances. Prevent eyes from direct laser. Before enabling the function, make sure no human or inflammable substances are in front of the laser lens.
  • Page 32: High Temperature Priority

    Handheld Thermography Camera User Manual Note Focus ring adjustment does not take effect in this mode. 3.1.5 High Temperature Priority Enable the high temperature priority function if you want to focus on the high temperature object in the observation scene. Select , and go to Device Settings →...
  • Page 33: Set Palettes

    Handheld Thermography Camera User Manual In fusion mode, the device displays the overlay effect of optical image and thermal image. In PIP (Picture in Picture) mode, the device displays thermal view inside the optical view. Note You can drag the corners of the PIP frame to move, enlarge, or contract it. In visual mode, the device displays the optical view.
  • Page 34: Set Alarm Mode Palettes

    Handheld Thermography Camera User Manual The hot part in the image are colored, and the else is blue. Blue Red The hot part in the image is colored red, and the else is blue. 3. Press to exit the setting interface. Note You can also press , and...
  • Page 35: Adjust Display Temperature Range

    Handheld Thermography Camera User Manual and the others with white hot palettes. Steps 1. Select from the main menu. 2. Tap the icons to select an alarm rule type. Table 3-2 Icon Description Icon Palettes Mode Description Set the temperature threshold, and the targets with Above Focus the temperature higher than the set value are displayed with fusion palettes.
  • Page 36: Adjust Digital Zoom

    Handheld Thermography Camera User Manual details of the area as possible. b. Press , or tap on the value on screen to lock or unlock a value. c. Press , or scroll the adjustment wheel on the screen to fine-tune the max. temperature and the min. temperature respectively.
  • Page 37: Chapter 4 Temperature Measurement

    Handheld Thermography Camera User Manual Chapter 4 Temperature Measurement The temperature measurement function provides the real-time temperature of the scene and display it on the left of your screen. This function is turned on by default. Note Your device will periodically perform a self-calibration to optimize image quality and measurement accuracy.
  • Page 38: Set Unit

    Handheld Thermography Camera User Manual Set temperature of the external optical material (e.g.: germanium window). Note When you install a macro lens, the device switches to macro mode automatically. In macro mode, settings such as display mode, distance, and optical transmissivity cannot be modified. 3.
  • Page 39: Set Measurement Tool

    Handheld Thermography Camera User Manual 4.3 Set Measurement Tool You can set temperature measurement parameters to improve the accuracy of temperature measurement. Before You Start Set parameters such as Humidity, External Optics Transmittance and Reflection Temperature. For detailed explanations, see Set Measurement Parameters. Steps 1.
  • Page 40: Measure By Line

    Handheld Thermography Camera User Manual Temp. Tap to display or hide the temperature measurement result. 5. Press The temperature of custom spot (e.g. P1) displays P1: XX. Note If the tool-specific emissivity and distance are set, the measurement is conducted based on the parameters.
  • Page 41: Measure By Rectangle

    Handheld Thermography Camera User Manual 4. Tap to modify temperature measurement parameters. Emissivity Refer to 19.1 Common Material Emissivity Reference to set the emissivity of your target. Distance Set the distance between the target and the device. Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the line can be displayed on the left of the screen.
  • Page 42: Measure By Circle

    Handheld Thermography Camera User Manual Set the distance between the target and the device. Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the rectangle area can be displayed on the left of the screen. 6.
  • Page 43: Measure Δt And Δt Alarm

    Handheld Thermography Camera User Manual Max./Min./Average Temperature Tap to enable the temperature types to display. The max. temperature, min. temperature, and average temperature of the circle area can be displayed on the left of the screen. 6. Press to save the settings. Note If the tool-specific emissivity and distance are set, the measurement is conducted based on the parameters.
  • Page 44: Temperature Alarm

    Handheld Thermography Camera User Manual 1) Input a tool name for the ΔT tool in Name of Tool. 2) Select Compared Object. Note You can compare the temperature difference between different or the same measurement tools, between a measurement tool and a number, etc. If you select Number as a compared object, input the value manually.
  • Page 45: Clear All Measurements

    Handheld Thermography Camera User Manual 2. Tap to enable Temperature Alarm. 3. Set the alarm parameters. Alarm Threshold When the tested temperature exceeds the threshold, the device sends alarm notification to the client software. It beeps if the audible warning is enabled. The rectangle flashes red if the rectangle tool is configured.
  • Page 46: Chapter 5 Route Inspection

    – Connect your PC to the device hotspot. Turn on and set up device hotspot by Settings → Connections → Hotspot. See Chapter 15 Set Device Hotspot for more instructions. 4. Click Device Management to add your device into the client. See the user manual of HIKMICRO Inspector for instructions.
  • Page 47: Perform Route Inspection

    ● Make sure your device has a memory card installed. See Appearance for instructions. ● Connect the device to the PC client, and make sure that your device has received inspection tasks from the PC client. See the user manual of HIKMICRO Inspector for instructions. Steps 1.
  • Page 48 Change the status if necessary. What to do next ● You can delete inspection tasks by selecting a task and tapping ● Upload the results to the PC client after finishing the route inspection. See the user manual of HIKMICRO Inspector for instructions.
  • Page 49: Upload Inspection Result And View Report

    5. Optional: Check a task or the desired inspect points and click Report for further analysis and report generation in HIKMICRO Analyzer. Note ● HIKMICRO Analyzer should be installed in your PC. Download the program from https://www.hikmicrotech.com/. ● For the operations instructions in HIKMICRO Analyzer, read the user manual from Help →...
  • Page 50 Handheld Thermography Camera User Manual User Manual. ● Please keep HIKMICRO Analyzer up-to-date for the best compatibility and user experience. Figure 5-5 Analysis in HIKMICRO Analyzer...
  • Page 51: Chapter 6 Picture And Video

    Handheld Thermography Camera User Manual Chapter 6 Picture and Video Insert memory card into the device, then you can record videos, capture snapshots, and mark and save important data. Note ● Device does not support capturing or recording when the menu is shown. ●...
  • Page 52 Handheld Thermography Camera User Manual 3) Optional: If a visual image is needed to be saved separately, enable Save Visual Image and set Visual Image Resolution. Note If the targets are in poor light condition, enable Flashlight. The device turns on the flashlight when capturing images.
  • Page 53: Record Video

    Accidentally stopped recordings are not saved. Recorded videos are saved in .mp4 format. These video clips can be played on local device, and any players that support this format (HIKMICRO Analyzer does not support playing this video format.). 2. In the live view interface, hold to start recording.
  • Page 54: View And Manage Local Files

    Videos of this format can be played on local device, or exported to MP4 videos, play by any other supported player. format .mp4 But, this format cannot be played by HIKMICRO Analyzer Radiometric images, Images can be viewed on local device, or exported and analyzed in format .jpeg HIKMICRO Analyzer.
  • Page 55: Manage Files

    Handheld Thermography Camera User Manual Task Operations 3. Tap , and select Rename. A soft keyboard is displayed. 4. Tap to delete the old name, and enter the new name for the album by touching the screen. 5. Tap to finish. 1.
  • Page 56 Handheld Thermography Camera User Manual Task Operations 2. Tap to select the album storing the files to be deleted. 3. In the album, tap , and tap the files to be deleted. 4. Tap . A prompt box appears on the interface. 5 Tap OK to delete the files.
  • Page 57: Local Analysis And Report Generation

    6. Enter the Title and Author for the report. Tap to generate the report. What to do next Refer to Export Files to export the PDF report for local analysis. Note You can analyze the radiometric image again on HIKMICRO Analyzer.
  • Page 58: Export Files

    For the first time connection, the driver will be installed automatically. What to do next You can import the captured snapshots to HIKMICRO Analyzer for further data analysis. See the User Manual of HIKMICRO Analyzer (embedded in the client software, Help → User Manual) for...
  • Page 59: Chapter 7 Calculate Area Size

    Handheld Thermography Camera User Manual Chapter 7 Calculate Area Size The device can calculate the size of rectangles and show results on screen. Steps 1. Select , and go to Measurement Settings → Area Size Calculation. 2. Enable Area Size Calculation. 3.
  • Page 60: Chapter 8 Distance Detection

    Handheld Thermography Camera User Manual Chapter 8 Distance Detection The laser range finder consists of a laser transmitter and a laser receiver. The device detects the distance to a target by measuring the time it takes for a laser pulse to reach the target and return to the laser receiver.
  • Page 61: Chapter 9 Geographic Location Display

    ● In an outdoor space, wait for a moment for the device to display its location. ● The location information is also attached in captured radiometric images. You can read the location by HIKMICRO Analyzer. ● Location display is only supported by models with satellite positioning modules.
  • Page 62: Chapter 10 Direction Display

    Declination Correction for instructions. Note The direction information is also attached in captured radiometric images. You can read the direction by HIKMICRO Analyzer. 10.1 Calibrate Compass Compass calibration is a must for correction direction display. You need to calibrate the compass when you enable the function for the first time.
  • Page 63: Magnetic Declination Correction

    Handheld Thermography Camera User Manual every possible directions. ● Calibration Level indicates the validity of calibration, higher level means more accurate compass reading. Calibration succeeds when the status bar in the live view interface shows, and Calibrated Level turns to 3. 3.
  • Page 64: Chapter 11 Connect Bluetooth

    Handheld Thermography Camera User Manual Chapter 11 Connect Bluetooth You can record and hear the sound contained in the videos or images via bluetooth headsets after pairing the device with bluetooth headsets successfully. Steps 1. Select , and go to Connections → Bluetooth. 2.
  • Page 65: Chapter 12 Set Led Light

    Handheld Thermography Camera User Manual Chapter 12 Set LED Light In live view mode, press to enable/disable the LED light. Or tap on the swipe-down menu.
  • Page 66: Chapter 13 Cast Device Screen To Pc

    Handheld Thermography Camera User Manual Chapter 13 Cast Device Screen to PC The device supports casting screen to PC by UVC protocol-based client software or player. You can connect the device to your PC via a type-C cable, and cast the real-time live view of the device to your PC.
  • Page 67: Chapter 14 Connect Device To Wi-Fi

    Handheld Thermography Camera User Manual Chapter 14 Connect Device to Wi-Fi Steps 1. Select , and go to Connections → WLAN. 2. Tap to enable Wi-Fi, and the searched Wi-Fi will be listed. Figure 14-1 Wi-Fi List 3. Select Wi-Fi to connect to and a soft keyboard is displayed. 4.
  • Page 68: Chapter 15 Set Device Hotspot

    Handheld Thermography Camera User Manual Chapter 15 Set Device Hotspot With the device hotspot, other equipment with Wi-Fi function can join the device for data transmission. Steps 1. Select , and go to Connections → Hotspot. 2. Tap to enable hotspot function. 3.
  • Page 69: Chapter 16 Thermal View Mobile Client Connection

    Handheld Thermography Camera User Manual Chapter 16 Thermal View Mobile Client Connection The device supports both Wi-Fi connection and hotspot. Connect the device to HIKMICRO Viewer, and you can control the device via mobile client. 16.1 Connect via Wi-Fi Before You Start Download and install HIKMICRO Viewer on your phone.
  • Page 70: Chapter 17 Hdmi Image Output

    Handheld Thermography Camera User Manual Chapter 17 HDMI Image Output You can view the image on the display unit for details with this function. If your device has a micro HDMI output interface, connect the device and a display unit to cast the image.
  • Page 71: Chapter 18 Maintenance

    Handheld Thermography Camera User Manual Chapter 18 Maintenance 18.1 View Device Information Select , and go to Local Settings → Device Settings → Device Information to view the device information. 18.2 Set Date and Time Steps 1. Select , and go to Local Settings → Device Settings → Time and Date. 2.
  • Page 72: Restore Device

    Handheld Thermography Camera User Manual 18.4 Restore Device Select , and go to Device Settings → Device Initialization → Restore Device to initialize the device and restore default settings. 18.5 Initialize Memory Card When a memory card is use on the handheld thermal camera for the first time, it needs to be initialized first.
  • Page 73: Chapter 19 Appendix

    0.98 Hard Paperboard 0.90 White Paper 0.90 Water 0.96 19.2 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for HIKMICRO thermal cameras.
  • Page 74: Device Communication Matrix

    Handheld Thermography Camera User Manual 19.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of HIKMICRO thermal cameras. 19.4 FAQ Scan the following QR code to get device common FAQ.
  • Page 75 Facebook: HIKMICRO Thermography LinkedIn: HIKMICRO Instagram: hikmicro_thermography YouTube: HIKMICRO Thermography E-mail: support@hikmicrotech.com Website: https://www.hikmicrotech.com UD32537B...

Table of Contents