Technical data

Heating element ratings
Bottom heating element
Top Heating element
Full oven (Top+Bottom)
Fan cooking
Grill
Oven light
Hot air fan motor
Cooling fan motor
Total rating
Operating voltage (50 Hz)
Dimensions of the recess
Height
Width
Depth
Oven
Height
Width
Depth
Oven capacity

Instructions for the Installer

The instructions given below are designed
specifically for a qualified installer and should
aid him or her to perform all installation,
adjustment, and maintenance operations with
absolute precision and in compliance with all
current legislation and regulations. We
strongly recommend that all operations for
the installation of your cooker be carryed out
by Qualified Personnel in accordance with
existing rules and regulations.
Electrical connection
Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of the
oven (see rating plate);
— your domestic wiring system has an efficient
earth connection in compliance with rules and laws in
force;
This appliance can be connected to the below listed
ceramic hobs:
1000 W
Type:
ZVD 868
800 W
(with 2 double-circuit cooking zones)
1800 W
Maximum power absorbed:
2000 W
Power supply voltage
1650 W
Type: ZK 630 L - ZK 630 F
25 W
(with 2 double-circuit cooking zones)
Maximum power absorbed
25 W
Power supply voltage
25 W
Type: ZC 6695
2075 W
(with 1 double-circuit cooking zone)
Maximum power absorbed
230 V
Power supply voltage
Type: ZC 6675
mm 600
(without double-circuit cooking zone)
mm 560
Maximum power absorbed
Power supply voltage
mm 550
Maximum Total Power Rate
mm 335
Oven + ceramic hob
mm 395
mm 400
53 l
— the wall socket or the omnipole switch used for
the electrical connection can easily be reached after the
oven is built in.
This appliance is delivered without an electric supply cable,
therefore, you will have to fit to it a supply cable with standard
plug, suitable for the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall socket. If you
require a direct connection to the electric network (mains), it will
be necessary to fit between the appliance and the mains an
omnipole switch, with a minimum gap between contacts of 3
mm, suitable for the required load and in compliance with rules
in force. The green & yellow ground wire must not be interrupted
by the switch, and should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases be laid out in
such a way as to ensure that it does not reach at any given
point a temperature 50°C higher than the ambient temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable: H07 RN-
F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
7,6 kW
(50 Hz) 230 V
7,6 kW
(50 Hz) 230 V
6,4 kW
(50 Hz) 230 V
5,8 kW
(50 Hz) 230 V
9,675 kW