Download Print this page
BEA FALCON EXXL Manual

BEA FALCON EXXL Manual

Motion sensor with explosion-proof housing for industrial doors

Advertisement

Quick Links

Visit website for
available languages of
this document.
DESCRIPTION
3
MICROWAVE SENSOR SPECIFICATIONS
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Mounting height:
Detection zone:
Min. detection speed:
Supply voltage:
Mains frequency:
Power consumption:
Output:
max. contact voltage:
max. contact current:
max. switching power:
Temperature range:
Housing certification:
Dimensions:
Tilt adjustment angle:
Materials:
Weight:
Cable length:
Cable diameter:
Electrical Access:
Norm conformity:
* Measured in optimal conditions
75.5355.05 FALCON EX 20200917
75.5355.05 FALCON EX 20200917
Motion Sensor with Explosion-Proof Housing
microwave doppler radar
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm
2
FALCON EX: 11.5 − 23 ft; FALCON EXXL: 6.5 − 11.5 ft;
FALCON EXWIDE: 11.5 − 21 ft
FALCON EX: 13 x 16 ft @ 16ft; FALCON EXXL: 13 x 6.5 ft @ 8.2 ft
FALCON EXWIDE: 30 x 11ft @ 21ft. (typical at 30° and field size 9)
2 in/s*
12 − 24 VAC ±10%; 12 − 24 VDC +30% / -10%
50 − 60 Hz
< 2W
relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30 W (DC) / 60 VA(AC)
-22 − 140 °F
(Adalet / Scott Fetzer Co., UL Listing # E81696)
UL Class I, Group BCD; Class II, Group EFG; Class III;
CENELEC: EExd IIC, IP66, NEMA 4x; 7BCD, 9EFG
9 in (L) x 7.5 in (W) x 5.5 in (H)
-90 − 30° in elevation
Copper-free aluminum (Housing); Powder-coated steel (Bracket)
10 lbs
100 ft
1
" max
4
" NPT pipe thread
3
4
R&TTE 1999/5/EC; EMC 2004/108/EC
Specifications are subject to change without prior notice.
All values measured in specific conditions.
FALCON EX
for Industrial Doors
FALCON EX: for normal to high mounting (11.5 - 23 ft)
FALCON EXXL: for low mounting (6.5 - 11.5 ft)
FALCON EXWIDE: for wide detection field
1
2
1. Explosion-proof housing
2. Microwave sensor
3. Adjustable bracket
Page 1 of 4
Page 1 of 4

Advertisement

loading

Summary of Contents for BEA FALCON EXXL

  • Page 1 FALCON EXWIDE: 11.5 − 21 ft Detection zone: FALCON EX: 13 x 16 ft @ 16ft; FALCON EXXL: 13 x 6.5 ft @ 8.2 ft FALCON EXWIDE: 30 x 11ft @ 21ft. (typical at 30° and field size 9) Min. detection speed:...
  • Page 2 YELLOW green   yellow yellow   gray DETECTION FIELD DIMENSIONS FALCON EX FALCON EXXL FALCON EXWIDE Mounting height: 16 ft Mounting height: 8 ft Mounting height: 11.5 ft Page 2 of 4 Page 2 of 4 75.5355.05 FALCON EX 20200917...
  • Page 3 LED SIGNALS LED flashes quickly LED flashes LED flashes slowly LED flashes x times LED is off NORMAL MODE no LED no detection detection red & green blinking power on / learn POSSIBLE SETTINGS BY REMOTE CONTROL ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE green x = number of flashes = value of parameter...
  • Page 4 BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.