2.3.2 Mounting the Device on a DIN Rail
1.
Make sure the rack mount adapters are installed on the correct side of the chas-
sis.
Note
The chassis features multiple mounting holes, allowing the rack mount adapters
to be installed up to 25 mm (1 in) from the face of the device.
Figure 2.1
2.
If required, install adapters on the opposite side of the device to protect from vi-
brations.
3.
Insert the device into the rack.
4.
Secure the adapters to the rack using the supplied hardware.
2.3.2

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RSG2200 can be equipped with panel/DIN
rail adapters pre-installed on each side of the chassis. The adapters allow the device
to be slid onto a standard 35 mm (1.4 in) DIN rail.
NOTICE
DIN rail mounting is not recommended for constant vibration environments.