Chapter 2
Installing the Device
Section 2.4

Mounting the Device

The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility. It can be equipped with
connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel.
IMPORTANT!
Heat generated by the device is channeled outwards to the enclosure. As such, it is recommended that
2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional
airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to
Chapter 5, Dimension
CONTENTS
Section 2.4.1, "Mounting the Device on a DIN Rail"
Section 2.4.2, "Mounting the Device to a Panel"
Section 2.4.1

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN rail adapters pre-installed on
each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
To mount the device to a DIN rail, do the following:
1.
Align the adapters with the DIN rails and slide the device into place.
Figure 2: DIN Rail Mounting
1. Panel/DIN Rail Adapter    2. DIN Rail    3. Screw
2.
Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.