Davey Microlene UV68-CA Installation And Operating Instructions Manual
Davey Microlene UV68-CA Installation And Operating Instructions Manual

Davey Microlene UV68-CA Installation And Operating Instructions Manual

Uv disinfection system

Advertisement

Quick Links

UV Disinfection System
Operating Instructions
Please pass these instructions on to the operator of this equipment.
Installation and
UV30-CA
NSF/ANSI STANDARD 55 CLASS A
System Tested and Certified by
NSF International against NSF/ANSI
55 for Disinfection Performance,
C
US
MODELS
System
(40mJ/cm
UV30-CA
UV68-CA
UV68-CA
Class A
Flow Rate
@ 70% UVT)
2
Consultez le manuel d'instructions pour les méthodes d'utilisation.
29.9 lpm (7.9 gpm)
This system or component conforms to NSF/ANSI 55 for the disinfection of micro-
biologically contaminated water that meets all other public health standards. The
system is not intended for the treatment of water that has an obvious contamination
or intentional source, such as raw sewage, nor is the system intended to convert
68.1 lpm (18 gpm)
If this system is used for the treatment of untreated surface waters or groundwater
under the direct influence of surface water, a device found to be in conformance for
cyst reduction under the appropriate NSF/ANSI standard shall be installed upstream
C
US
WARNING /
System Tested and Certified by
ADVERTISSEMENT
NSF International against CSA
B483.1 and NSF/ANSI 55
Ce système est fabriquer de composant qui sont conforme à la norme NSF / ANSI
for Disinfection Performance, Class A
55 pour la désinfection de l'eau contaminée par des microorganismes et rencontre
toutes les autres normes de santé publique. Ce système n'est pas conçu pour le
Ce Système est certifié par NSF
traitement de l'eau qui a une contamination bactérienne évidente ou, de façon
International CSA B483.1 et NSF
intentionnelle comme des eaux usées, et n'est pas conçu pour transformer des eaux
/ ANSI55 pour sa performance de
désinfection class A
Si ce système est utilisé pour le traitement des eaux de surface ou sous terraine
non traitées ou des eaux souterraines avec une influence directe avec une eau de
surface, il est nécessaire d'installer un appareil jugé conforme pour la réduction des
kystes sous la norme NSF / ANSI appropriée en amont du système.
See instruction manual for use conditions.
wastewater to microbiologically safe drinking water.
of the system.
AS/NZS: 3497
In the event of a
Dans le cas d'une défaillance du
system failure, boil
système, vous devrez faire bouillir
water prior to use
l'eau avant consumation.
usées en eau potable pour la consumation humaine.
C
US
System Tested and Certified by
NSF International against CSA
B483.1 and NSF/ANSI 55
for Disinfection Performance, Class A
Ce Système est certifié par NSF
International CSA B483.1 et NSF
/ ANSI55 pour sa performance de
désinfection class A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Microlene UV68-CA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Davey Microlene UV68-CA

  • Page 1 UV Disinfection System Installation and Operating Instructions UV68-CA UV30-CA NSF/ANSI STANDARD 55 CLASS A System Tested and Certified by NSF International against NSF/ANSI 55 for Disinfection Performance, Class A MODELS Flow Rate System (40mJ/cm @ 70% UVT) See instruction manual for use conditions. Consultez le manuel d’instructions pour les méthodes d’utilisation.
  • Page 2 Congratulations on purchasing this ultraviolet disinfection system. By purchasing a Microlene UV Disinfection System you are receiving not only a high quality product but also peace of mind. Protecting your water supply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home protecting from microbiological contamination.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Considerations ....................4 Before You Begin ......................5 Water Quality Parameters ....................5 Assembly ........................6 System Sizing .......................7 Location ........................7 Installation ........................8 System Disinfection ....................11 Cleaning the Quartz Sleeve..................11 Cleaning the UV Sensor .....................12 Operation ........................12 MCXS Controllers .....................13 Controller Power-up Sequence .................13 Controller Operational Screens Operational Screens ........14 Lamp Countdown Sequence................15...
  • Page 4: Safety Considerations

    Safety Considerations Although your UV system has been manufactured to the highest safety standards, care must be followed when operating and/or maintaining your system. Please read the instructions. - This appliance contains a UV-C emitter. - Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation.
  • Page 5: Before You Begin

    18. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This product is not to be used for general lighting / illumination. Before You Begin The following will be needed for installing the UV system: Tools •...
  • Page 6: Assembly

    High Output (HO) Lamp System UV30-CA / UV68-CA GLAND NUT CONTROLLER DM320006 MCXS-CONT O-RING DM300038 UV LAMP UV151LAMP (suit UV68-CA) DMRL-600HO (suit UV30-CA) SLEEVE SPRING LAMP KEY DM310039 QUARTZ SLEEVE GLOW PLUG UV151SLEEVE DM300016 Complete (suit UV68-CA) Assembly includes Teflon Plug DMRQ-600 O-Ring (suit UV30-CA)
  • Page 7: System Sizing

    System Sizing All DAVEY NSF UV systems are rated for a specific flow rate in water that meets the quality parameters on page 5. The NSF systems have a built in flow restrictor to ensure flow does not exceed the specification design.
  • Page 8: Installation

    Installation Step 1: The chamber can be installed either horizontally, or vertically using the clamps provided. Vertical installation is the preferred method with the inlet at the bottom (lamp connection at the top) as it allows any air that may be in the lines to be easily purged from the system.
  • Page 9 Step 6: Once the system has been plumbed in, gently remove the quartz sleeve from its packaging being careful not to touch the length with your hands. The use of cotton gloves is recommended for this procedure as oils from the hands can leave residue on the sleeve and lamp which can ultimately block the UV light from getting to the water.
  • Page 10 Step 11: Always hold UV lamps by their ceramic ends, not by the lamp quartz. Remove the lamp from its packaging. Again, the use of cotton gloves is recommended. Remove the lamp key from the lamp’s connector. The lamp key will only be used if the Extra Smart Controller has been purchased to swap out with the standard controller supplied on initial purchase.
  • Page 11: System Disinfection

    System Disinfection With a new installation, or any time the UV system is shut down for service, without power, or is inoperative for any other reason, the lines in the home or facility could be contaminated. Use the following steps to fully disinfect the lines throughout the entire home or facility.
  • Page 12: Cleaning The Uv Sensor

    Step 10: Dry the sleeve with separate cloth. Step 11: Replace the o-ring and slide the sleeve back into the chamber following steps 7 and 8 from the installation section of the manual. Cleaning the UV Sensor Depending on the water quality, the UV sensor may require periodic cleaning. At a minimum, the UV sensor should be cleaned on an annual basis.
  • Page 13: Mcxs Controllers

    MCXS Controllers A full colour LCD screen provides the user with a detailed description of the system’s performance in addition to providing any applicable fault messages and system diagnostics. All controllers include an “infinite expandability port” located on the right side of the controller. Simply plug in a UV sensor module into the expandability port of a controller for the system to monitor the UV intensity of the system.
  • Page 14: Controller Operational Screens Operational Screens

    Operational Screens On systems without the UV monitor, the default screen shows the Microlene Home Screen. At any point during operation the user is able to scroll through the Microlene Home Screen, Lamp life remaining, QR Code, Contact Info and Maintenance Parts screens by pressing the button located on the front of the controller.
  • Page 15: Lamp Countdown Sequence

    Lamp Countdown Sequence The system counts down the number of days until a lamp change is required. At thirty days remaining, the display screen will change to a yellow caution indicator. At seven days remaining, the sytem will additionaly repeat an audible chirp. Past the zero day threshold, the display screen changes to solid red with a continuous buzzer.
  • Page 16: Qr Codes

    System Service Suggested Controllers will display the System Service Suggested Screen every 6 months to remind consumers to maintain both their UV and other prefiltration. This will serve as a prompt only and will not put the system into alarm. To clear this condition simply press the button located below the screen.
  • Page 17: System Troubleshooting

    System Troubleshooting Hard Alarms: The following give a constant audible alarm. If present, the solenoid valve is closed, and the remote alarm transmits the alarm. System Display Problem Resolution Reset lamp protection circuit -unplug unit for 10 seconds. The system has Replace the lamp with the part detected a problem as indicated on the silver label...
  • Page 18 If the water is used for human consumption during this period, the water must be boiled (minimum 20 minutes at a full boil) prior to consumption. Alternatively, use Davey Acquasafe to disinfect the water.
  • Page 19: Temperature Management Devices

    Temperature Management Devices Your Microlene UV Disinfection System is designed to run continuously to ensure optimal disinfection. However, during periods when no water is drawn through the system, the energy from the disinfection process can cause the temperature of the water inside the chamber to rise.
  • Page 20 REMOTE ALARM CONNECTION MODULE: Allows for a connection to a remote device such as a buzzer, light, alarm system, PLC, etc., via a pair of contacts. In normal operation the OK and COM contacts will be connected, and in a fault condition (Low UV, Lamp fail, Power Fail), the Fault and COM contacts will be connected.
  • Page 21: Microlene Nsf High Output System Specifications

    Microlene NSF High Output System Specifications EQUIPMENT SPECIFICATIONS Multi-Use / Residential systems (high output lamps) MODEL UV30-CA UV68-CA 29.9 lpm 68.1 lpm NSF Class A Flow Rate 7.9 gpm 18 gpm 40mJ/cm2 @ 70% UVT 1.8 m 4.08 m Port Size 1”MNPT 1 ½”MNPT Electrical Input...
  • Page 22 Performance Data Sheet (on all NSF/ANSI Standard 55, Class A Systems) System Tested and Certified by NSF International against NSF/ANSI 55 for Disinfection Performance, Class A Model UV30-CA UV68-CA NSF Class A Flow Rate 29.9 lpm 68.1 lpm (40mJ/cm @ 70% 7.9 gpm 18 gpm UVT)
  • Page 23: Microlene Systems Limited Warranty Statement

    Microlene Systems Limited Warranty Statement Products manufactured by Davey Water Products Pty. Ltd. are warranted to the original user only to be free of defects in material and workmanship for a period as specified below. This warranty only applies to the original purchaser and is not transferable.
  • Page 24: Warranty

    To the fullest extent permitted by law Davey disclaims any warranties regarding the accuracy, completeness or reliability of App data. Davey is not responsible for any direct or indirect loss, damage or costs to the User arising from its reliance on internet connectivity.