5.4 Potting

5.4
Potting
If sensor is buried or permanently submerged, terminal box must be encapsulated with
silicon dielectric gel (non-toxic, transparent and self-healing gel)
NOTICE
Do not pot meter before electrical connections have been made.
● Mix the two components of the potting kit well and pour into terminal box.
● Let cure for approximately 24 hours at approximately 25°C (77°F). Curing time increases
Horizontal orientation
Note
Gel can be penetrated with test instruments or be removed in case of cable replacement.
38
by 100% per -10°C (-18°F).
Vertical orientation
SITRANS F M MAG 3100 sensor
Operating Instructions, 09/2012, A5E03005599-02