Installation of indoor unit

Step one: choosing installation location
Recommend the installation location to the client and then confirm it with the client.
Step two: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe.
2. Open a piping hole with the diameter of Ф70 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
Step three: outlet pipe
1. The pipe can be led out in the
direction of left, right or rear.
left
back
Step four: connect the pipe of indoor unit
1. Take out the left and right screw cover and then remove the screws on air-inlet
panel to remove the panel.
2. After confirming the direction of outlet pipe,
loosen the screws at the upper and lower
adjusting baffle to let the connection pipe
/drain pipe connects the indoor unit.
right
air-inlet panel
30
Indoor
5-10
left
back
upper and lower adjusting baffle
screw
outdoor
Φ70
right