Installation

Before mounting and removing the sensor, make sure that no
pressure is applied to the system. Horizontal mounting recom-
mended for high medium temperatures.
1. Screw the sensor into a G1
process fitting.
2. Tighten the sensor with a
spanner.
Tightening torque: 20 Nm.
The housing (A) is freely rotat-
able.
The unit is adaptable for various G1 process fittings (G1 adapters to
be ordered separately as accessories).
Welding adapter
Weld the adapter first. Then mount the sensor.