Environmental Data; Technical Standards - XCHARGE C6EU Series Installation And Operation Manual

Hide thumbs Also See for C6EU Series:
Table of Contents

Advertisement

3.4 Environmental data

Environmental Data
Ground load bearing
Ingression protection
Temperature range – Operation
Temperature range – De-rating
Temperature range – Storage
Operating Relative Humidity
Storage Relative Humidity
Humidity
Operational noise level
Atmospheric Pressure
Altitude
Network

3.5 Technical Standards

The C6EU products were already approved by TÜV Rheinland according to the technical
standards below:
Technical Standards
Healthy, safety and general
requirements
EMC
Radio
Copyright | C6EU SERIES Installation and Operation Manual, Version 1.6
At least 450 kg
IP 54
- 25 °C to + 50 °C,
- 40 °C to 55 °C (optional, with additional heat pump)
+ 50 °C to +70 °C
- 40 °C to + 80 °C
5 % to 95 %, no condensing on the surface
95 %, no condensing on the surface
Up to 95% no condensation on the surface
<65 dB in rated output power
79 KPa - 106 KPa
2000 m (maximum altitude without power derating)
GSM/WCDMA/LTE/4G/LAN
Table 3.4.1 Environmental data of C6EU
EN 50385: 2017
EN 61851-1: 2011
EN 61851-23: 2014
EN 61851-24: 2014
IEC 61851-21:2018
EN 301 489-1 V2.2.0 (2017-03)
EN 301 489-3 V2.1.1 (2017-03)
EN 301 489-52 V1.1.0 (2016-11)
EN 300 330 V2.1.1 (2017-02)
EN 301 511 V12.5.1 (2017-03)
EN 301 980-1 V11.1.1 (2016-07)
EN 301 980-2 V11.1.2 (2017-08)
Table 3.5.1 Technical standard of C6EU