Removing And Fitting The Cable Guard; Connecting The Submersible Drop Cable; Riser Pipe; Maximum Installation Depth Below Water Level [M] - Grundfos SP14-27 Installation And Operating Instructions Manual

Table of Contents

Advertisement

3. Lift the pump part by means of pipe clamps fitted to the
extension pipe. See fig. 21.
Fig. 21 Lifting the pump into position
4. Place the pump part on top of the motor.
5. Fit and tighten the nuts. See table below.
Make sure that the coupling between the pump
Caution
and motor engages properly.
The bolts and nuts securing the straps to the pump must be
cross-tightened to the following torques:
Bolt/nut
M8
M10
M12
M16
SP 215, 50 Hz, with more than 8 stages
SP 215, 60 Hz, with more than 5 stages
When fitting the motor to the pump part, cross-tighten the nuts to
the following torques:
Staybolt diameter
5/16 UNF
1/2 UNF
M8
M12
M16
M20
Make sure that the pump chambers are aligned
Caution
when assembly has been completed.

7.2 Removing and fitting the cable guard

If the cable guard is screwed on to the pump, it should be
removed and fitted by means of screws.
Make sure that the pump chambers are aligned
Caution
when the cable guard has been fitted.
12

7.3 Connecting the submersible drop cable

7.3.1 Grundfos motors
Before connecting the submersible drop cable to the motor, make
sure that the cable socket is clean and dry.
To facilitate the connection of the cable, lubricate the rubber parts
of the cable plug with non-conducting silicone paste.
Tighten the screws holding the cable to these torques [Nm]:
MS 402:
MS 4000:
MS 6000:
MMS 6:
MMS 8000:
MMS 10000: 18
MMS 12000: 15

7.4 Riser pipe

If a tool, e.g. a chain pipe wrench, is used when the riser pipe is
fitted to the pump, the pump must only be gripped by the pump
discharge chamber.
The threaded joints on the riser pipe must all be well cut and fit
together to ensure that they do not work loose when subjected to
torque reaction caused by the starting and stopping of the pump.
The thread on the first section of the riser pipe which is to be
screwed into the pump should not be longer than the threads in
the pump.
If noise may be transmitted to the building through the pipework,
we recommend that you use plastic pipes.
Note
When plastic pipes are used, secure the pump by an unloaded
straining wire to be fastened to the discharge chamber of the
pump. See fig. 22.
Torque
[Nm]
18
35
45
120
150
Torque
Fig. 22 Fixing the straining wire
[Nm]
When connecting plastic pipes, use a compression coupling
18
between the pump and the first pipe section.
50
Where flanged pipes are used, the flanges should be slotted to
18
take the submersible drop cable and a water indicator hose, if
fitted.
70
150

7.5 Maximum installation depth below water level [m]

280
Grundfos MS 402:
Grundfos MS 4000: 600
Grundfos MS 6000: 600
Grundfos MMS:
Franklin motors:
2.0
3.0
4.5
20
18
We recommend plastic pipes for 4" pumps only.
150
600
350