Fitting The Cable Plug To The Motor; Fitting The Cable Guard - Grundfos SQE-NE Series Installation And Operating Instructions Manual

Hide thumbs Also See for SQE-NE Series:
Table of Contents

Advertisement

6.4 Fitting the cable plug to the motor

Warning
The motor plug must under no
circumstances be removed by the user.
The following description is exclusively
intended for service personnel.
If the motor cable is to be replaced, see
section 5.1 General.
The cable with plug must be fitted or
removed by an authorised Grundfos
service workshop or a similarly qualified
person.
The cable plug supplied with the motor is factory-
greased. Check that the plug is greased correctly.
To fit the cable plug, proceed as follows:
1. Check that the cable is of the correct type, cross-
section and length.
2. Check that the mains on the location has correct
connection to earth.
3. Check that the motor socket is clean and dry.
Make sure that the loose gasket has been fitted.
4. Press the cable plug onto the motor socket.
The plug cannot be fitted wrongly. See fig. 8.
Fig. 8
5. Fit and tighten the four screws (1 - 1.5 Nm).
See fig. 8.
When the plug has been fitted, there must not be a
clearance between the motor and the cable plug.

6.5 Fitting the cable guard

To fit the cable guard, proceed as follows:
1. Make sure that the submersible drop cable lies
flat in the cable guard.
2. Place the cable guard in the groove in the cable
plug. The two flaps of the cable guard must
engage with the upper edge of the pump sleeve.
See fig. 9.
Fig. 9
3. Fasten the cable guard to the pump suction
strainer with the two self-tapping screws
supplied. See fig. 10.
Fig. 10
13

Advertisement

Table of Contents
loading

Table of Contents