2.6.10 Unit discharges white mist

2.6.11 Swing flap does not operate

ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
Check
Check installation conditions.
Check installation conditions.
Air filter.
Fan motor.
Symptom
Swing flap does not
operate
Detail
Humid site.
Dirty site.
Oil mist.
Dirty heat exchanger.
Dirty air filter.
Defective fan motor.
Check
Check swing flap motor
Check indoor unit PCB
2
Troubleshooting
|
Detail
Some functions can force
the swing flap into a fixed
position, although swing
mode is selected on the
remote controller. This is
not a unit error, but a
control function to
prevent draft to the
customer.
Connector connection
Service manual
45