SC936 Chassis Manual
5.
The air shroud includes perforations on the bottom. These perforations can be
removed if motherboard components interfere with the air shroud placement.
Do not remove more perforations than necessary.
6.
Install the rear fans by sliding each fan into the fan housing on the chassis.
Checking the Server's Air Flow
1.
Make sure there are no objects to obstruct airflow in and out of the server. In
addition, if you are using a front bezel, make sure the bezel's filter is replaced
periodically.
2.
Do not operate the server without drives or drive trays in the drive bays. Use
only recommended server parts.
3.
Make sure no wires or foreign objects obstruct air flow through the chassis.
Pull all excess cabling out of the airflow path or use shorter cables.
4.
The control panel LEDs inform you of system status. See "Chapter 3: System
Interface" for details on the LEDs and the control panel buttons.
In most cases, the chassis power supply and fans are pre-installed. If you need to
install fans continue to the Systems Fan section of this chapter. If the chassis will be
installed into a rack, continue to the next chapter for rack installation instructions.
4-6

System Fans

Five heavy-duty fans provide cooling for the chassis. These fans circulate air through
the chassis as a means of lowering the chassis internal temperature.
Release Tab
Figure 4-16: System Fan
4-8