Table 2. Events organized by severity (continued)
Message String
Event ID
FQXSPSD0002L
Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been
disabled due to a detected fault.
FQXSPSD0005L
Array [ComputerSystemElementName] is in critical condition.
FQXSPSD0006L
Array [ComputerSystemElementName] has failed.
FQXSPSD0007L
Array critical asserted on drive [arg1] in the enclosure/chassis (MTM-
S/N: [arg2]).
FQXSPSD0008L
Array failed on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]).
FQXSPSE4000I
Certificate Authority [arg1] has detected a [arg2] Certificate Error.
FQXSPSE4006I
SSL data in the Management Controller [arg1] configuration data is
invalid. Clearing configuration data region and disabling SSL.
FQXSPSR0001N
Sensor [SensorElementName] has transitioned to non-recoverable
from a less severe state.
FQXSPUN0019M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
FQXSPUN0023N
Sensor [SensorElementName] has transitioned to non-recoverable.
FQXSPUP0007L
Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName].
FQXSPUP4000I
Please ensure that the Management Controller [arg1] is flashed with
the correct firmware. The Management Controller is unable to match
its firmware to the server.
FQXSPUP4003I
[arg1] firmware mismatch internal to system [arg2]. Please attempt to
flash the [arg3] firmware.
FQXSPUP4004I
XCC firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the XCC firmware to the same level on all
nodes/servers.
FQXSPUP4005I
FPGA firmware mismatch between nodes/servers [arg1] and [arg2].
Please attempt to flash the FPGA firmware to the same level on all
nodes/servers.

List of XClarity Controller events

This section lists all messages that can be sent from the XClarity Controller.
• FQXSPBR4000I: Management Controller [arg1]: Configuration restored from a file by user [arg2].
This message is for the use case where a user restores a Management Controller configuration from a file.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0027
User Action:
Information only; no action is required.
22
ThinkSystem SR860 V2 Messages and Codes Reference
Severity
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error

Advertisement